0.08 mm2 ~ 0.5 mm2 Ground shield Max. 10 m
Not required for RS-232C, required for RS-422 Refer to Figure A.
iii

STE 58761

NOTE!

FOR EUROPEAN UNION (EU)

In the European Union (EU), there are following limitations and notes to approve the CE Marking EMC Direction. In other countries and areas, it is not necessary to apply to these limitations and notes.

(1)Setup conditions

The following type of power line transformer must be used.

Frequency:

50 or 60 Hz

Secondary voltage:

3-phase, 200~230 VAC

Power capacity:

Min. 2.7 kVA

(2) Input power condition

3.5 mm2 ~ 5.5 mm2

Core wires:

Voltage short interruption: 0.5 cycle

(3)Ground

Core wires:

3.5 mm2 ~ 5.5 mm2

Ground condition:

Exclusive ground line for robot ground impedance must be

 

less than 100Ω

(4) External input/output line/Optional input/output line

Core wires:

0.08 mm2 ~ 0.5 mm2

Shield:

Ground shield

Cable length:

Max. 10 m

Manufacturing method:

Refer to Figure A.

Signal ground:

Voltage potential between signal ground PGBA and controller

 

frame ground F.G. must be same.

(5)Serial communication line

Only 1 of 4 serial communication ports (connector name; J1~J4) can be used at the same

time.

Core wires: Shield:

Cable length: Twisted pair:

Manufacturing method: