general

Installation information

Model Number Description

FC B B 020 1 C

P0 A

0 G 1 0 A

A 2 M 000 0

0 1 0 0 0

A A 000

000 0

0 0 0 A 0 0

1

5

10

15

20

25

30

35

40

44

Digits 1, 2 — unit type

FC = fan-coil

FF = force flo

Digit 3 — cabinet type

A= vertical concealed

B= vertical cabinet

C= horizontal concealed

D= horizontal cabinet

E= horizontal recessed

F= vertical wall hung

H = vertical recessed

J= vertical cabinet slope top

K= low vertical concealed

L= low vertical cabinet

M= inverted vertical cabinet

N= inverted vertical recessed

Digit 4 — development sequence “B”

Digits 5, 6, 7 — unit size 020 040 080 030 060 100

120

Digit 8 — unit voltage

1 = 115/60/1

4 = 230/60/1

2 = 208/60/1

9 = 220/50/1

3 = 277/60/1

 

Digit 9 — piping system/placement

A = no piping, RH, w/o aux drn pan B = no piping, LH, w/o aux drn pan C = no piping, RH, w/ aux drn pan D = no piping, LH, w/ aux drn pan E = no piping, RH, w/o aux drn pan,

extended end pocket

F = no piping, LH, w/o aux drn pan, extended end pocket

G = no piping, RH, w/ aux drn pan, extended end pocket

H = no piping, LH, w/ aux drn pan, extended end pocket

J = piping package, RH K = piping package, LH

L = piping package, RH, extd end pkt M = piping package, LH, extd end pkt

Digits 10, 11 — design sequence

Digit 12 — inlets

A = front toe space

B= front bar grille

C= front stamped louver

D= bottom stamped louver

E= bottom toe space

F= back duct collar

G = back open return

H = back stamped louver

Digit 13 — fresh air damper 0 = none

A= manual,bottomopening

B= manual, back opening

C= manual, top opening

D= auto, 2-position, bottom opening

E= auto, 2-position, back opening

F= auto, 2-position, top opening

G= auto, economizer, bottom opening

H= auto, economizer, back opening

J= auto, economizer, top opening

K= no damper, bottom opening

L= no damper, back opening M= no damper, top opening

Digit 14 — outlets

A = front duct collar

B= front bar grille

C= front stamped louver

D= front quad grille

G = top quad grille

H = top bar grille

J = top duct collar

Digit 15 — color

 

 

0

= no paint (concealed units only)

1

= deluxe beige

4

= driftwood grey

2

= soft dove

5

= stone grey

3

= cameo white

6

= rose mauve

Digit 16 — tamperproof locks/leveling feet

0 = none

A = locking panel

B= keylock access door

C= locking panel & keylock access door

D= leveling feet

F = locking panel w/ leveling feet G = keylock panel, keylock access door

w/ leveling feet

Digit 17 — motor

A = free discharge

B = high static

Digit 18 — coil

A= 2 row cooling/heating

B= 3 row cooling/heating

C= 4 row cooling/heating

D= 2 row cooling/1 row heating

E= 2 row cooling/2 row heating

F= 3 row cooling/1 row heating

G= 2 row cooling only

H= 3 row cooling only

J= 4 row cooling only

K= 2 row cooling/heating w/ elec heat

L= 3 row cooling/heating w/ elec heat M= 4 row cooling/heating w/ elec heat P = 2 row cooling/heating w/1 row heat Q = 2 row cooling/heating w/2 row heat R = 3 row cooling/heating w/1 row heat

Digit 19 — coil series 2 = 144 FPF

Digit 20 — coil air vent

A = automatic air vent

M= manual air vent

Digits 21, 22, 23 — electric heat (208V derate)

000 = no electric heat

010 = 1.0 kW (0.75 kW)

015 = 1.5 kW (1.1 kW)

020 = 2.0 kW (1.5 kW)

025 = 2.5 kW (1.9 kW)

030 = 3.0 kW (2.3 kW)

040 = 4.0 kW (3.0 kW)

050 = 5.0 kW (3.8 kW)

060 = 6.0 kW (4.5 kW)

070 = 7.0 kW (5.3 kW)

08 0= 8.0 kW (6.0 kW)

100 = 10.0 kW

Digit 24 — reheat coil

0 = none B = hot water coil A = steam coil

Digit 25 — disconnect switch 0 = none

D = disconnect switch

Digit 26 — filter 0= none

1= 1” throwaway filter

2= 1” throwaway pleated media filter 3= 1” throwaway, qty 2

4= 1” throwaway pltd media, qty 2 5= 1” throwaway, qty 3

6= 1” throwaway pltd media, qty 3 7= 1” throwaway, qty 4

8= 1” throwaway pltd media, qty 4

Digit 27 — main control valve 0 = none

A= 2-way, 2-position, NO (30 psig)

B= 3-way, 2-position, NO (28 psig)

C= 2-way, 2-position, NC (30 psig)

D= 3-way, 2-position, NC (20 psig)

E= 2-way, 2-position, NO (50 psig)

F= 3-way, 2-position, NO (28 psig)

G= 2-way, 2-position, NC (50 psig)

H= 3-way, 2-position, NC (28 psig)

UNT-SVX07A-EN

5

Page 5
Image 5
Trane UniTrane Fan-Coil & Force Flo Air Conditioners, UNT-SVX07A-EN manual General, Model Number Description