a certain period (for details, see the IEEE 802.3af specification).

„Capacitive Detection: If the port and capacitive detection are enabled, the capacitances state reads in the voltage result from the constant current. This is then subtracted from the pre-capacitance voltage to get a charge rate. If this charge rate is within the window of the PD signatures, the device is considered to be discovered.

„Start: Showing with a tick symbol, the system initializes and resets successfully.

„ And then, click Apply to carry into effect.

„Port: The index of PoE ports.

„Enable State: Check it to enable the PoE function to the port.

„Power Limit From: Check it to decide the power limit method.

¾Classification: When this check box is ticked, the system will limit the power supply to the powered device in accordance with the related class.

„Legacy: Check it to support the legacy power devices.

„Priority: Pull down the selection menu item to choose the priority of power supplying.

„Port Limit (<15400) mW: User can key in the power limit value which is under 15.4 Watts.

„Mode: Displays the operating mode of the port.

„Current (mA): Displays the operating current of the port.

„Voltage (V): Displays the operating voltage of the port.

„Power (mW): Displays the power consumption of the port.

„Determined Class: Displays the PD’s class.

„ And then, click Apply to carry into effect.