System Log Configuration interface
Event Configuration
User can select the system log events. When selected events occur, the system will send out the log information. Also, per port log events can be selected.
•System event selection: 4 selections – Device cold start, Power status, SNMP Authentication Failure, and
Device cold start: When the device executes cold start action, the system will produce a log message
Power status: When the device power status has changed, the system will produce a log message
SNMP Authentication Failure: When the SNMP authentication fails, the system will produce a log message
•Port event selection: Select the per port events. Per port have 3 selections – Link UP, Link Down, and Link UP & Link Down. Disable means no event is selected.
Link UP: The system will produce a log message when port connection is up only
Link Down: The system will produce a log message when port connection is down only
Link UP & Link Down: The system will produce a log message when port connection is up and down