42 THE CONTROL SYSTEM
Thermocouple – Cook Chamber (Figure 47) | Thermocouple – Electrical Compartment (EC) |
Type K Thermocouple. Thermocouple measures the temperature of the recirculating impingement airflow. If the display indicates 999ºF/C, the Thermocouple is “open,” resulting in an F7 Fault.
To replace a defective CC Thermocouple:
1.Ensure “Cool Down” process is completed (“Cool Down” message will disappear upon completion) and unplug the oven.
2.Remove Right Side Panel.
3.Pull back insulation where necessary.
4.Replace defective thermocouple with P/N
5.Reset insulation and reattach Right Side Panel.
This Type K Thermocouple measures the temperature of the Electrical Compartment. If the temperature within the Electrical Compartment is above 158ºF (70°C), the control will display an F6 Fault.
To replace a defective EC Thermocouple:
1.Ensure “Cool Down” process is completed (“Cool Down” message will disappear upon completion) and unplug the oven.
2.Remove Right Side Panel.
3.Disconnect defective thermocouple from the I/O Control Board and install new one (P/N
4.Reattach Right Side Panel.
| 48 |
|
|
| 49 |
NUMBER | PART | PART NUMBER |
48 | Thermocouple – Cook Chamber | |
49 | Screw – Thermocouple – Cook Chamber | 101688 |
: Removing the Cook Chamber (CC) Thermocouple |
|