Turbo Chef Technologies HHB-8136 Color Code Line Voltage, Color Code Low/Control Voltage

Models: HHB-8041 HHB-8099 HHB-8085 HHB-8097 HHB-8115 HHB-8134 HHB-8028 HHB-8029 HHB-8136

1 117
Download 117 pages 1.18 Kb
Page 90
Image 90

HIGH H BATCH SCHEMATIC

63

H H B OVEN SCHEMATIC

Figure 61. Inside of fold-out page. Rev 2 Board, VFD Display, Single Phase, 280/240 VAC, 60 Hz

NOTE: Schematic shows the oven with door open and without power applied.

Color Code (Line Voltage)

BL – Blue = Line V (208/240)

BR – Brown = Line V (208/240)

OR – Orange = 240 Line Input for Tap 3 on all Transformers

BK – Black = Hi-Temp 240 VAC Wire

Color Code (Low/Control Voltage)

BK – Black = 24 VDC Common

OR – Orange = Status Input

WH – White = Control Input

RD – Red = +24 VDC

Line Voltage Components

Blower Motor

Blower Motor Controller

Cooling Fans

Fuses

Heater Element

Power Supply, +24VDC

Rack Oscillator Motor

Relay

Solid State Relay

Thermostat – Cooling Fan

Thermostat – Hi-Limit

Voltage Sensor Module

Wiring Harness – Line Voltage

Low Voltage Components

Cable – Smart Card Connector

Display, VFD

Door Switch

I/O Control Board

Keypad

Ribbon Connector – Display

Smart Card Reader

Thermocouple – CC

Thermocouple – EC

Wiring Harness – Low Voltage

I/O CONTROL BOARD COMPONENT IDENTIFICATION

AND TEST POINT LOCATIONS

Figure 62, page 64

J2

40-Pin Connector for LV Harness

J3

3-Pin Connector for VFD Display

J4

14-Pin Connector for Keypad

J5

26-Pin Connector for Display Data

J6

RS-232 Connector

 

(for computer hookup, if necessary)

RJ11

Connector for Smart Card Cable

U15

EPROM Socket

P1

Voltage Reference 0-5 VDC

P3

Blower Controller Pin Configuration

SKP1

Beeper

R51

Beeper Volume Adjustment