DIAGNOSING AN ISSUE | 21 |
Troubleshooting:
F6: EC TEMP (Electrical Compartment (EC) Temperature High)
Does the oven have room to ventilate?
(not tightly enclosed by other appliances or fixtures?)
YES
NO
Is the oven in an area of moderate
temperature (120ºF (49ºC) or cooler)?
Move oven to open area or remove items that are in close proximity.
NO
Relocate oven to
cooler area.
YES
Are both Cooling
Fans rotating?
YES
Check for
obstructions in the airflow and remove them.
NO
Is Wiring Harness properly connected? Check Cooling Fan Thermostat, I/O Control Board, and Fans. (See page 61 for schematic.)
YES
Replace defective
component – either Cooling Fan Thermostat (page 43), I/O Control Board (page 39), or Fan (page 33).
NO
Correct wiring.
Troubleshooting:
F7: THERMO (Thermocouple Open)
Is the CC
Thermocouple an
open circuit?
Using the Ohm
Meter, measure at
CCThermocouple should measure
approx.
YES
YES
NO
|
|
|
|
|
|
|
| Is the open Thermocouple properly |
|
|
| Correct connection. | |
|
| NO |
| |||
| connected to the I/O Control Board? |
|
| |||
|
|
| ||||
|
|
|
|
| ||
| (See page 61 for schematic.) |
|
|
|
| |
|
|
|
|
| ||
|
|
|
|
|
|
|
Replace the defective Thermocouple.
(page 42)
Replace I/O Control Board.
(page 39)