Table 2. Local Mode Programming Instructions

* = Default Settings

Function Code(s)

Operation

Normal Indication

Remarks

 

 

 

 

20 or 30

1. Swipe

Program Card. While in programming

mode, at the Series 600 Keyboard

Comm (RS232)

numeric keypad, enter Function Code 20 (Port 0) or 30 (Port 1).

Main Port 0 (20)

 

 

 

AUX Port 1 (30)

LED (2) turns on.

 

Baud Rate

 

 

 

 

2.At Series 600 Keyboard numeric keypad, enter the applicable number (1 through 9) to select baud rate per list below.

1

= 300

6

= 9600*

2

= 600

7

= 19200

3

= 1200

8

= 38400

4

= 2400

9

= 57600

5

= 4800

 

 

LED (2) turns off.

3.Program the next function code or exit programming mode by entering 99 on Series 600 Keyboard numeric keypad or by swiping the Program Card.

21 or 31

1. Swipe Program Card. While in programming mode, at the Series 600 Keyboard

Main Port 0 (21)

 

numeric keypad, enter Function Code 21 (Port 0) or 31 (Port 1).

AUX Port 1 (31)

 

 

 

Stop Bits

 

LED (2) turns on.

 

 

 

2.

At Series 600 Keyboard numeric keypad, enter the number of stop bits (1 or 2)per list

 

 

below.

 

 

1 = one stop bit

 

 

2 = two stop bits*

 

 

LED (2) turns off.

 

3.

Program the next function code or exit programming mode by entering 99 on Series

 

 

600 Keyboard numeric keypad or by swiping the Program Card.

Series 600 POS Keyboard

19

Page 24
Image 24