Table 5. Remote Programming Mode Commands

OP CODE

MNEMONIC/DESCRIPTION

 

COMMAND/ACKNOWLEDGEMENT

(HEX)

 

 

 

 

 

 

 

 

AD

RAWED

COMMAND:

ADx<CR>

 

Puts keyboard in row and column mode

AD

= Op Code

 

used for diagnostics.

x

0

= user codes

 

 

 

1

= row and column

 

 

<CR>

= terminate command (0D hex)

 

 

ACKNOWLEDGEMENT: NONE

 

 

 

 

AE

SECURE

COMMAND:

AEx<CR>

 

Used to lock keyboard from remote

AE

= Op Code

 

location.

x

0

= unsecured

 

 

 

1

= secured

 

 

<CR>

= terminate command (0D hex)

 

 

ACKNOWLEDGEMENT: NONE

 

 

 

 

AF

COMMENT

COMMAND:

AFxxxx-xxxx<CR>

 

Use when notes or comments are to be

AF

= Op Code

 

placed in the download file. All data is

xx

= Comments

 

ignored up to the carriage return <CR>.

<CR>

= terminate command (0D hex)

 

 

ACKNOWLEDGEMENT: NONE

 

 

 

 

 