Image 52

Table 5. Remote Programming Mode Commands

OP CODE

MNEMONIC/DESCRIPTION

 

COMMAND/ACKNOWLEDGEMENT

(HEX)

 

 

 

 

 

 

B0

LIGHT

COMMAND: B0Lx<CR>

 

Provides on/off control for keyboard light

B0

= Op Code

 

emitting diode (LED) indicators. PC mode

L

= lamp

 

for NUM and CAP Lock lights is default.

x

= on/off

 

 

<CR>

= terminate command (0D hex)

 

 

L:

0, 1, 2, 3, P in ASCII, where 0 = all. P is

 

 

 

used for PC emulation of NUM and CAPS

 

 

 

Lock

 

 

x:

PC mode

 

 

 

1 = on; 0 = off

 

 

ACKNOWLEDGEMENT: NONE

 

 

 

 