Table 2. Local Mode Programming Instructions

* = Default Settings

Function Code(s)

Operation

Normal Indication

Remarks

 

 

 

 

 

 

24 or 34

1.

Swipe

Program Card.

While in programming

mode, at the Series 600 Keyboard

Main Port 0 (24)

 

numeric keypad, enter Function Code 24 (Port 0) or 34 (Port 1).

AUX Port 1 (34)

 

LED (2) turns on.

 

 

Word Length

 

 

 

 

 

 

 

 

 

2.

At Series 600 Keyboard numeric keypad, enter the applicable number (7 or 8) to

 

 

select word length per list below.

 

 

 

 

7 = 7 data bits

 

 

 

 

8 = 8 data bits*

 

 

 

LED (2) turns off.

 

 

 

3.

Program the next function code or exit programming mode by entering 99 on Series

 

 

600 Keyboard numeric keypad or by swiping the Program Card.

 

 

 

 

 

 

25 or 35

1.

Swipe

Program Card.

While in programming

mode, at the Series 600 Keyboard

Comm (RS232)

 

numeric keypad, enter Function Code 25 (Port 0) or 35 (Port 1).

Main Port 0 (25)

 

LED (2) flashes.

 

 

AUX Port 1 (35)

 

 

 

 

 

 

 

 

Prefix

2.

At the auxiliary keyboard, press the desired key or type the desired key sequence.

 

 

 

Note that the maximum number of key codes is limited to 24 – this is equivalent to

 

 

approximately 12 key strokes.

 

 

 

 

 

 

If the Series 600 Keyboard beeps and

 

 

 

 

 

LED (2) turns off while entering key

 

 

 

 

 

codes at the auxiliary keyboard, you

 

 

 

 

 

have exceeded 24 key codes.

 

 

 

 

 

Repeat steps 1 and 2.

 

3.

At the Series 600 Keyboard, press ENTER.

 

 

 

LED (2) turns off.

 

 

 

4.

Program the next function code or exit programming mode by entering 99 on Series

 

 

600 Keyboard numeric keypad or by swiping the Program Card.

 

 

 

 

 

 

Series 600 POS Keyboard