Ultimate Technology 600 POS Copying Keyboard Setup Data Cloning, Source Unit Destination Unit

Models: 600 POS

1 81
Download 81 pages 58.6 Kb
Page 66
Image 66

COPYING KEYBOARD SETUP DATA (CLONING)

Once a keyboard has been programmed, the parameters can be copied from the source keyboard to other keyboards. This feature saves time and reduces errors when programming more than one keyboard. It is also useful for remote keyboard setup and when making changes in key codes. Downloading of keyboard parameters can be done using one of two methods. The first method is initiated by using the GETSET command (Table 5) issued from the host. This sends all setup data such as baud rate, key codes and macros to the main port of the keyboard in command format.

The second method is performed in the local programming mode with the source and target keyboards connected together. This method can only be used when the main ports are configured as RS232 type ports. To use this method proceed as follows.

1.Connect a cable, UTC Part No. CAB20135 or equivalent, and external 5-volt power adapter, UTC Part No. CAB20136 or equivalent to the source and target Series 600 Keyboards as shown below. Schematics showing the pin and signal data for the cable and power adapter are provided in Appendix B.

SOURCE UNIT

DESTINATION UNIT

SERIES 500 Main

CAB20135

Main

SERIES 500

RS232

Port

RS232

Port

Aux

RS232

Port

CAB20136

+5VDC Supply

Figure 5. Keyboard Downloading Connection Diagram

Series 600 POS Keyboard

61

Page 66
Image 66
Ultimate Technology 600 POS manual Copying Keyboard Setup Data Cloning, Source Unit Destination Unit, Series 500 Main