Uniden SC230 owner manual Setting Close Call Options

Models: SC230

1 99
Download 99 pages 61.18 Kb
Page 73
Image 73

Setting Close Call Options

1. Press

Menu

then turn the scroll control until Close Call

appears. Then press E. Close Call feature options appear.

2. Turn the scroll control to select an option.

Close Call Only: Lets you set the scanner only for Close Call searching. The scanner does not scan frequencies or channels when this option is turned on.

To select this option, press E.

Set CC Bands: Lets you select the Close Call band settings. You can turn the following bands on or off.

VHF Low (25.0000 - 54.0000 MHz) Air Band (108.0000 - 136.9750 MHz) VHF High (137.0000 - 224.9800 MHz) UHF (400.0000 - 512.0000 MHz) 800MHz+ (806.0000 - 956.0000 MHz)

Use the scroll control to select a band, press E, then use the scroll control to select On or Off and press E. Turning off undesired bands speeds up Close Call operation. (The Close Call feature does not work for frequencies greater than 956 MHz.)

Set CC Alert: Lets you select how the scanner alerts you when it receives a Close Call signal. You can select any of the following options.

Beep+Light (the scanner beeps and the backlight turns on when it receives a Close Call signal)

Light (the backlight turns on when it receives a Close Call signal)

Beep (the scanner beeps when it receives a Close Call signal)

None (the scanner does not alert)

Turn the scroll control to display an option, then press E.

Set CC Override: Lets you select how the Close Call feature works with other scanning activities. If you turn this option off, when the scanner detects a Close Call signal, CC Found! and E to Listen appear for about 3 seconds. Press E when this appears to jump to and hold on the frequency.

Using the Close Call Feature

73

Page 73
Image 73