PRINT DRUM INDEX MECHANISM CONVERSION

MAINTENANCE

PRINT DRUM INDEX MECHANISM CONVERSION

1- Using a 5/64” hex wrench, loosen the Nylon Tip Set Screw located in the top rim of the Print Drum.

FIGURE 57

2- Remove the Print Drum Dust Cover.

3- To relieve the spring tension on the index mechanism, ro- tate the Print Drum approximately 3/4 turn. The Index Com- pression Springs will now be in the fully extended (relaxed) position.

4- Using a 5/32" hex wrench, remove the two Index Ramp Mount- ing Screws which are located on the under side of the Coder Baseplate. The Index Ramp will be reinstalled in the oppo- site orientation to allow the Print Drum to turn in the reverse direction.

FIGURE 58

FIGURE 59

FIGURE 60