MAINTENANCE

MOUNTING CONFIGURATION CONVERSION

LEFTHAND/RIGHTHAND FIELD CONVERSION

Mounting configuration conversion involves the “mirror image” reversal of the pivot arm assembly that holds the inking system and the tension arm assembly which provides the printing pressure. Indexing printers require the additional reversal of the index ramp and repositioning of the index ring.

Universal Non-Porous CLP Coders are assembled at the factory for either right-hand or left-hand mounting. If field conversion is required, the following steps will guide you through the conversion process.

PIVOT ARM & INKING SYSTEM ASSEMBLY CONVERSION

1- Loosen the Pivot Arm Adjustment Knob and rotate the Inking System away from the Print Drum slightly. 2- Remove the Inking System Assembly from the coder by removing the 2 socket head cap screws on

the underneath side of the Pivot Arm.

3- Remove the Pivot Screw and lift the tension adjustment assembly off of the coder.

4- Remove the Pivot Arm Cap and lift the Pivot Arm assembly off it’s axle.

5- Reinstall the Pivot Arm on the axle in the opposite or “mirrored” orientation and replace the Pivot Arm Cap.

6- Remove the Position Adjusting Screw and reinstall in the reverse position.

7- Replace the tension adjusting assembly and the Pivot Screw.

INKING SYSTEM

 

ASSEMBLY

 

PIVOT ARM

 

PIVOT SCREW

TENSION

PIVOT ARM CAP

ADJUSTMENT

ASSEMBLY

 

POSITION ADJUSTING

SCREW

 

PIVOT ARM

 

ADJUSTMENT KNOB

 

LEFT HAND

RIGHT HAND

CONFIGURATION

CONFIGURATION

FIGURE 54

8 - Remove the Baseplate Plug from the bottom side of the Inking System Assembly Baseplate (See Figure 55).

9 - Reinstall the Baseplate Plug in the threaded hole on the opposite side of the Baseplate. Thread the Plug into the Baseplate only until the flush with the Baseplate surface.

30

Page 30
Image 30
Universal Laser Systems CLP-100NI-NPRT manual Pivot ARM & Inking System Assembly Conversion