SCANNING

MEMORY SCANNING

Memory Bank Scan

When the Memory Bank feature is engaged, the scanner sweeps only memory channels in the current Memory Bank. However, if the Memory Bank Link Scan feature is enabled, you may sweep the memory channels in several Memory Banks which you have selected.

To enable the Memory Bank Link Scan feature:

1.Set the radio to the Memory mode by pressing the [MR(SKIP)] key, if necessary.

2.Press and hold in the [VFO(PRI)] key for one second, then rotate the DIAL knob to

select the first Memory Bank (“BANK 1” ~ “BANK10”) you wish to sweep using Memory Bank Link Scan.

3. Press the [F] key momentarily. The current Memory Bank will now be swept during Memory Bank Scan. A “decimal point”

will be appended between the “N” and “K” of the Memory Bank number indication (such as BAN.K 2).

4.Repeat steps 2 and 3 above, to append the “decimal point” to any other Memory Banks you wish to sweep.

5.Now, press and hold in the [MR(SKIP)] key for one second to initiate the Memory Bank Link Scan.

6.To remove a Memory Bank from the Memory Bank Link Scan, repeat steps 2 and 3 above, to delete the “decimal point” from the Memory Bank number indication.