SET (MENU) MODE

The VX-177Set Mode, already described in parts of many previous chapters, is easy to activate and set. It may be used for configuration of a wide variety of transceiver param- eters, some of which have not been detailed previously. Use the following procedure to activate the Set Mode:

1. Press the [F] key, then press the [0(SET)] key to enter the Set mode.

2. Rotate the DIAL knob to select the Set Mode Item to be ad- justed.

3. Press the [F] key momentarily to enable adjustment of the Set Mode Item.

4. Rotate the DIAL knob to adjust or select the parameter to be changed on the Set Mode Item selected in above step.

5.After completing your selection and adjustment, press the PTT switch momentarily to save the new setting and exit to normal operation.

1)Some Set Mode Items (like Set Mode Item 46: TN FRQ) require that the

[F]key be pressed after setting of the parameter, and before exiting to nor- mal operation.

2)Two Set Mode Item numbers (in the factory default, Set Mode Item 25: LAMP, and 32: RESUME) will blink while selecting the Set Mode Item; this indicates that this Set Mode Item has been assigned to the [7(P1)] or [8(P2)] key of the keypad.

SET MODE ITEM

FUNCTION

AVAILABLE VALUES

(DEFAULT: BOLD ITALIC)

 

 

 

 

1

[APO]

Setting of the Automatic Power-Off feature.

OFF / 0.5H - 12.0 H

2

[AR BEP]

Selects the Beep option during ARTS operation.

INRANG / ALWAYS / OFF

3

[AR INT]

Selects the Polling Interval during ARTS operation.

25 SEC / 15 SEC

4

[ARS]

Enables/Disables the Automatic Repeater Shift function.

ARS. ON / ARS.OFF

5 [BCLO]

Enables/Disables the Busy Channel Lock-Out feature.

BCL. ON / BCL.OFF

6

[BEEP]

Enables/Disables the beeper.

KEY+SC / KEY / OFF

7

[BELL]

Selects the number of CTCSS/DCS Bell ringer repetitions.

OFF / 1T / 3T /

 

 

 

 

5T / 8T / CONT

8

[BSY.LED]

Enables/Disables the BUSY LED while the Squelch is open.

LED. ON / LED.OFF

9

[CLK.SFT]

Shifting of the CPU clock frequency.

SFT.OFF / SFT. ON

10

[CWID]

Enables/disables the CW identifier during ARTS operation.

TX OFF / TX ON

11 [CW WRT]

Programs and activates the CW Identifier.

---

12

[DC VLT]

Indicates the DC Supply Voltage.

---

13

[DCS.COD]

Setting of the DCS code.

104 DCS codes (023)

14

[DCS.N/R]

Enables/Disables “Inverted” DCS code decoding.

T/RX N, RX R,

 

 

 

 

TX R, T/RX R

15

[DT DLY]

Setting of the DTMF Autodialer Delay Time.

50MS / 100MS / 250MS /

 

 

 

 

450MS / 750MS / 1000MS

16

[DT SPD]

Setting of the DTMF Autodialer Sending Speed.

50MS / 100MS

17

[DT WRT]

Programming of the DTMF Autodialer.

---

18

[ECS.CDR]

Setting the Receiver Pager Code for the Enhanced CTCSS

(R05 47)

 

 

 

Paging & Code Squelch.

 

19

[ECS.CDT]

Setting the Transmitting Pager Code for the Enhanced

(T05 47)

 

 

 

CTCSS Paging & Code Squelch.

 

20

[EDG.BEP]

Enables/Disables the Band-edge beeper while selecting the

BEP.OFF / BEP. ON

 

 

 

frequency via the DIAL knob.

 

 

 

 

 

 

70