VIVOTEK

notifyserver

0~31

0

6/6

Indicate which notification server is

 

 

 

 

scheduled.

 

 

 

 

One bit represents one application

 

 

 

 

server (server_i0~i4).

 

 

 

 

bit0 (LSB) = server_i0.

 

 

 

 

bit1 = server_i1.

 

 

 

 

bit2 = server_i2.

 

 

 

 

bit3 = server_i3.

 

 

 

 

bit4 = server_i4.

 

 

 

 

For example, enable server_i0,

 

 

 

 

server_i2, and server_i4 as

 

 

 

 

notification servers; the notifyserver

 

 

 

 

value is 21.

 

 

 

 

 

weekday

0~127

127

6/6

Indicate which weekday is

 

 

 

 

scheduled.

 

 

 

 

One bit represents one weekday.

 

 

 

 

bit0 (LSB) = Saturday

 

 

 

 

bit1 = Friday

 

 

 

 

bit2 = Thursday

 

 

 

 

bit3 = Wednesday

 

 

 

 

bit4 = Tuesday

 

 

 

 

bit5 = Monday

 

 

 

 

bit6 = Sunday

 

 

 

 

For example, to detect events on

 

 

 

 

Friday and Sunday, set weekday as

 

 

 

 

66.

 

 

 

 

 

begintime

hh:mm

00:00

6/6

Start time of the weekly schedule.

 

 

 

 

 

endtime

hh:mm

24:00

6/6

End time of the weekly schedule.

 

 

 

 

(00:00~24:00 indicates schedule

 

 

 

 

always on)

 

 

 

 

 

prefix

string[16]

<blank>

6/6

Indicate the prefix of the filename.

 

 

 

 

 

cyclesize

200~

100

6/6

The maximum size for cycle

 

 

 

 

recording in Kbytes when choosing to

 

 

 

 

limit recording size.

 

 

 

 

(not used in FD8362E)

 

 

 

 

 

reserveamount

0~

100

6/6

The reserved amount in Mbytes

 

 

 

 

when choosing cyclic recording

 

 

 

 

mechanism.

 

 

 

 

 