8.17 Virtual input (capability.nvi > 0)

Note: Change virtual input (manual trigger) status.

Method: GET

Syntax:

http://<servername>/cgi-bin/admin/setvi.cgi?vi0=<value>[&vi1=<value>][&vi2=<value>] [&return=<return page>]

PARAMETER

 

VALUE

DESCRIPTION

vi<num>

 

state[(duration)nstate]

Ex: vi0=1

 

 

 

Setting virtual input 0 to trigger state

 

 

Where "state" is 0, 1. “0”

 

 

 

means inactive or normal

 

 

 

Ex: vi0=0(200)1

 

 

 

 

 

state while “1” means

Setting virtual input 0 to normal state, waiting 200

 

 

 

 

 

active or triggered state.

milliseconds, setting it to trigger state.

 

 

 

 

 

Where "nstate" is next

Note that when the virtual input is waiting for next

 

 

 

 

 

state after duration.

state, it cannot accept new requests.

 

 

 

 

 

 

 

return

 

<return page>

Redirect to the page <return page> after the request is

 

 

 

completely assigned. The <return page> can be a full

 

 

 

URL path or relative path according the current path. If

 

 

 

you omit this parameter, it will redirect to an empty

 

 

 

page.

 

 

 

 

 

 

 

 

Return Code

 

Description

 

200

 

The request is successfully executed.

 

 

 

400

 

The request cannot be assigned, ex. incorrect parameters.

 

 

Examples:

 

 

 

setvi.cgi?vi0=0(10000)1(15000)0(20000)1

 

No multiple duration.

 

 

 

setvi.cgi?vi3=0

 

 

VI index is out of range.

 

 

 

setvi.cgi?vi=1

 

 

No VI index is specified.

 

 

 

 

503

 

The resource is unavailable, ex. Virtual input is waiting for next state.

 

 

Examples:

 

 

 

setvi.cgi?vi0=0(15000)1

 

 

 

setvi.cgi?vi0=1

 

 

 

 

 