VIVOTEK

i<0~(m-1)>_begintime

hh:mm

18:00

4/4

Begin time of

 

 

 

 

schedule mode.

 

 

 

 

 

i<0~(m-1)>_endtime

hh:mm

06:00

4/4

End time of

 

 

 

 

schedule mode.

 

 

 

 

 

i<0~(m-1)>_win_i<0~2>_enable

<boolean>

0

4/4

Enable motion

 

 

 

 

window.

 

 

 

 

 

i<0~(m-1)>_win_i<0~2>_name

string[14]

<blank>

4/4

Name of

 

 

 

 

motion window.

 

 

 

 

 

i<0~(m-1)>_win_i<0~2>_left

0 ~ 320

0

4/4

Left coordinate

 

 

 

 

of window

 

 

 

 

position.

 

 

 

 

 

i<0~(m-1)>_win_i<0~2>_top

0 ~ 240

0

4/4

Top coordinate

 

 

 

 

of window

 

 

 

 

position.

 

 

 

 

 

i<0~(m-1)>_win_i<0~2>_width

0 ~ 320

0

4/4

Width of

 

 

 

 

motion

 

 

 

 

detection

 

 

 

 

window.

 

 

 

 

 

i<0~(m-1)>_win_i<0~2>_height

0 ~ 240

0

4/4

Height of

 

 

 

 

motion

 

 

 

 

detection

 

 

 

 

window.

 

 

 

 

 

i<0~(m-1)>_win_i<0~2>_objsize

0 ~ 100

0

4/4

Percent of

 

 

 

 

motion

 

 

 

 

detection

 

 

 

 

window.

 

 

 

 

 

i<0~(m-1)>_win_i<0~2>_sensitivity

0 ~ 100

0

4/4

Sensitivity of

 

 

 

 

motion

 

 

 

 

detection

 

 

 

 

window.

 

 

 

 

 

7.17 Tempering detection settings

Group: tampering_c<0~(n-1)>for n channel product (capability.tampering > 0)

 

NAME

 

VALUE

DEFAULT

SECURITY

DESCRIPTION

 

 

 

 

 

(get/set)

 

 

 

 

 

 

 

 

enable

 

<boolean>

0

4/4

Enable or disable tamper detection.

 

 

 

 

 

 

 

threshold

0 ~ 255

32

4/4

Threshold of tamper detection.

 

 

 

 

 

 

 

duration

10 ~ 600

10

4/4

If tampering value exceeds the „threshold‟ for

 

 

 

 

 

 

 

User's Manual - 151

Page 151
Image 151