Unity 552 User’s Manual

 

 

 

 

 

External Input/Output Interfaces

 

 

 

 

 

 

Contact Closure GPIO DB-9 Female

 

 

 

 

 

Connector Pin

Input/Output

Description

 

 

 

 

 

1

 

Alarm Common

 

 

 

 

 

2

 

Alarm Normally Open

 

 

 

 

 

3

 

Contact Closure Common

 

 

 

 

 

4

 

No Connection

 

 

 

 

 

5

Input

Contact Closure GPIO Input

 

 

 

(Factory use only)

 

 

 

 

 

6

 

Alarm Normally Closed

 

 

 

 

 

7

 

Contact Closure Normally Closed

 

 

 

 

 

8

 

Contact Closure Normally Open

 

 

 

 

 

9

NA

Ground

 

 

 

 

 

 

Power DC IN 12 V 5 A

 

 

 

 

 

Connector

Input/Output

Description

 

 

 

 

 

Standard IEC

Input

115 or 230 V AC

 

 

 

 

 

Technical Specifica- tions

The following tables detail the technical specifications for the iPump 562.

RF Characteristics

Table 1.3: iPump 562 RF Characteristics

RF Characteristics

RF Input

Connector Type F

 

 

Input Frequency Range

950 - 2150 MHz

 

 

Input Level Range

-25 to -65dBm

 

 

Maximum Aggregate Input Power

-8 dBm at max input signal

 

 

Input Impedance

75 ohms

 

 

Input VSWR

< 2.5:1

 

 

Input Noise Figure

8 dB MAX at minimum input level

 

 

L.O. Leakage at Input

< -55 dBm

 

 

Demodulator

FEC Rate 1/2, 2/3, 3/4, 5/6, or 7/8 (1.0 to 45 MBaud) ½, 2/3,

DVB-S QPSK

¾, 4/5, 5/6, 7/8, 9/10 (2 to 30 MBaud) 2/3, ¾, 5/6, 8/9, 9/10

(3 to 30 MBaud) Convert Symbol Rate Fs to Transport Rate

DVB-S2 QPSK

Ft by: (2R*Fs)*(188/204)=Ft, where 'R' is inner FEC code

DVB-S2, 8PSK

ratio, either R=1/2, 2/3, 3/4, 5/6, or 7/8.

 

 

Max Symbol-rate

S2 = 30 Msps; S1 = 45 Mbps

 

 

www.wegener.com

800092-01 Rev. A

5

Page 15
Image 15
Wegener Communications manual Technical Specifica- tions, IPump 562 RF Characteristics