Western Telematic CMS-16 manual Enter+++Enter Resident Disconnect Sequence, Connect

Models: CMS-16

1 59
Download 59 pages 31.71 Kb
Page 51
Image 51

WTI CMS-16; Console Management Switch -- User's Guide

[Enter]+++[Enter] Resident Disconnect Sequence

The Resident Disconnect Sequence is issued to disconnect your resident port from another port. For example, if you are communicating via Port 3, and Port 3 is connected to Port 4, the Resident Disconnect Sequence would be used to disconnect Port 3 from Port 4. Although the default Resident Disconnect Sequence is [Enter]+++[Enter], the command format and Logoff Character can also be redefined via the Port Configuration Menus as described in Section 5.5.3. Note that a one character disconnect command can also be selected.

Availability: Supervisor / User

Format: [Enter]xxx[Enter]

Where "x" is the selected Logoff Character, and the default character is "+".

Response:

Verbose: The CMS will send the "Disconnected" message, followed by the Port Status Screen.

Terse: 3

/C Connect

Establishes a bi-directional connection between two ports. For more information and command line examples, please refer to Section 7.1. There are two different types of port connections:

Resident Connect: If the /C command specifies one port name or number, your resident port will be connected to the specified port.

Third Party Connect: If the /C command specifies two port names or numbers, the unit will connect the two ports indicated. A Third Party Connect command must be issued from a third port with "Supervisor" command capability. "User" ports cannot initiate a Third Party Connect.

Note:

Ports with "User" command capability can only connect to ports that share the same Port Password.

Ports with "Supervisor" command capability are allowed to connect to all other ports.

Availability: Supervisor / User

Format: /C <x> [x] [Enter]

Where x is the number or name of the port(s) to be connected.

Response:

file:///C/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (51 of 59) [11/15/2000 10:52:03 AM]

Page 51
Image 51
Western Telematic CMS-16 manual Enter+++Enter Resident Disconnect Sequence, Connect