WTI CMS-16; Console Management Switch -- User's Guide

command is invoked, the network connection will be reset without warning, and must then be re-established in order to communicate with the unit via Network.

Availability: Supervisor Only

Format: /T [Enter]

Response: None (NIC Card is reset, Network Connection is broken)

/U Save Parameters

Sends CMS configuration parameters to an ASCII text file as described in Section 8.

Availability: Supervisor Only

Format: /U [Enter]

Response: The CMS will send a series of command lines.

/UF Upgrade Firmware

When new versions of the CMS operating firmware become available, this command is used to update the existing firmware as described in Section 9. Note that this command will only function at the Network Port and at Setup Ports One and Two.

Availability: Supervisor Only

Format: /UF [Enter]

Response: The CMS will display a menu which offers the options to retain existing CMS parameters, default parameters, or abort the upgrade procedure.

/W Display Port Parameters (Who)

Displays configuration of an individual port, but does not allow the user to change parameters. Ports with User Level command capability cannot display parameters for other ports. Normally, the Port Parameters screen will not include the Port Password. Note however, that when the Supervisor Mode is active, the /WP option can be used to display the password for the target port. For more information, please refer to Section 6.4.

Availability: Supervisor / User

Format: /W[P] [x] [Enter]

Where:

PWhen the "P" option is included (e.g. /WP 5), the Port Parameters screen will list the password for each port, if defined. (Supervisor Mode Only).

xIs the port number or name. To display parameters for the Network Port, enter an "N". If the "x" argument is omitted, parameters for your resident port will be displayed.

file:///C/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (56 of 59) [11/15/2000 10:52:03 AM]

Page 56
Image 56
Western Telematic CMS-16 manual Save Parameters, UF Upgrade Firmware, Display Port Parameters Who