TECHNICAL INFORMATION

SETUP MENU – 48 VDC (120 VAC/60HZ) MODELS

To access the SETUP MENU, press the RED and GREEN buttons on your CONTROL PANEL (or SWRC) at the same time. To exit the Setup Menu, press the ON/OFF MENU button or use the down MENU HEADING button until you reach the USER MENU (menu headings 1 – 8).

MENU HEADING

 

MENU ITEM

 

 

 

Inverter Setup

9

Set Grid Usage

 

 

Set Low Battery cut out VDC

 

 

Set LBCO delay minutes

 

 

Set Low battery cut in VDC

 

 

Set High battery cut out VDC

 

 

Set search watts

 

 

Set search spacing

Battery Charging

10

Set Bulk volts DC

 

 

Set Absorption time h:m

 

 

Set Float volts DC

 

 

Set Equalize volts DC

 

 

Set Equalize time h:m

 

 

Set Max Charge amps AC

 

 

Set Temp Comp

AC Inputs

11

Set Grid (AC1) amps AC

 

 

Set Gen (AC2) amps AC

 

 

Set Input lower limit VAC

 

 

Set Input upper limit VAC

Gen Auto Start Setup

12

Set Load Start amps AC

 

 

Set Load Start delay min

 

 

Set Load Stop delay min

 

 

Set 24 hr start volts DC

 

 

Set 2 hr start volts DC

 

 

Set 15 min start volts DC

 

 

Read LBCO 30 sec start VDC

 

 

Set Exercise period days

 

 

Set Maximum run time h:m

Gen Starting Details

13

Set RY7 Function

 

 

Set Gen warmup seconds

 

 

Set Pre Crank seconds

 

 

Set Max Cranking seconds

 

 

Set Post Crank seconds

Auxiliary Relays R9 R10

14

Set Relay 9 volts DC

 

 

R9 Hysteresis volts DC

 

 

Set Relay 10 volts DC

 

 

R10 Hysteresis volts DC

 

 

Set Relay 11 volts DC

 

 

R1 Hysteresis volts DC

Bulk Charge Trigger Timer

15

Start Bulk Time H:M

Low Battery Transfer (LBX)

16

Set Low Battery transfer VDC

 

 

Set Low Battery cut in VDC

Battery Selling

17

Set Battery Sell volts DC

 

 

Set Max Sell amps AC

Grid Usage Timer

18

Set Start Charge time h:m

 

 

End Stop Charge time h:m

SELECTION

RANGE

FLT SELL SLT LBX

32.0– 70.0

00 - 255

20.0– 71.0

20.0– 66.0

00 - 240

20 – 255

40.0– 64.0

00:00 – 23:50

40.0– 64.0

40.0– 64.0

00:00 – 23:50

01 - 35

LeadAcid Nicad

00 - 63

00 - 63

80 - 111

128 - 149

00 - 63

00.0– 25.5

00.0– 25.5

20.0– 71.0

20.0– 71.0

20.0– 71.0

20.0– 71.0

00 - 255

00:00 – 23:50

GlowStop Run

16 - 255

00 - 255

00 - 15

00 - 255

20.0– 71.0

00.2– 25.6

20.0– 71.0

00.2– 25.6

20.0– 71.0

00.2– 25.6

00:00 – 23:50

20.0– 71.0

20.0– 71.0

40.0– 64.0

01 - 35

00:00 – 23:50

00:00 – 23:50

DEFAULT SETTINGS

FLT

44.0

15

52.0

64.0

48

59

57.6

02:00

53.6

57.6

02:00

30

LeadAcid

60

30

108

132

33

05.0

05.0

49.2

47.2

45.2

44.0

30

08:00

Run

60

10

10

30

58.0

04.0

59.0

04.0

60.0

04.0

00:00

45.2

52.0

53.6

30

21:00

21:00

USER

SETTINGS

Page

126

2001 Xantrex Technology, Inc.

Telephone: 360/435-8826

SW Series Inverter/Charger

5916 - 195th Street N. E.

Fax: 360/435-2229

Part No. 2031-5

Arlington, WA 98223

www.traceengineering.com

Rev. C: February 2001

Page 134
Image 134
Xantrex Technology owner manual Setup Menu 48 VDC 120 VAC/60HZ Models, 126