AC SOURCE

INSTALLATION

AC SOURCE

NEUTRAL-TO-GROUND “BOND” is

provided by an external AC source for

 

 

the entire AC system

INVERTER

(AC Terminal Block)

AC HOT IN

AC NEUTRAL IN

EARTH GROUND

CHASSIS GROUND

RY1

AC HOT OUT

Figure 14, Neutral-To-Ground Bond Switching: Neutral Bonded To GroundAC NEUTRAL OUTManual background

NEUTRAL-TO-GROUND SWITCHING RELAY (Provided in the AC installation): Connects the neutral from external AC source, and neutral of the AC panel loads together when AC is applied to the inverter input.

AC PANEL

 

 

(RV/Marine)

 

 

HOT

NEUTRAL

The neutral conductor

 

 

should not be

 

connected to the

 

equipment grounding

 

 

 

 

conductors or

GROUND

 

enclosures.

 

 

Figure 13, Neutral-To-Ground Bond Switching: External AC Source Connected

Figure 14, graphically shows the current path if no ground switching was employed in a multiple AC source system. If one neutral was tied to the AC subpanel ground buss and another neutral tied to the vehicle or chassis ground, the two different ground points would now form a current carrying conductor with the frame/hull (chassis ground) acting as the “wire” between the two different ground points. This means any ground point in the vehicle or boat becomes a potential current carrying conductor, which could result in an electric shock. Any form of Ground Fault Circuit Interrupter (GFCI) such as those found in bathroom outlets, will pop if a ground loop (a situation where a voltage difference exist between multiple ground points) is created.

If, however, the ground switching system were in place, it would ensure that there is only one ground point in the system at all times. This would be either the vehicle/boat ground or the external AC source ground, but never both at once.

NEUTRAL-TO-GROUND “BOND” is provided by the external AC source

AC SOURCE

INVERTER

(AC Terminal Block)

NEUTRAL-TO-GROUND SWITCHING RELAY (Provided in the AC installation): Connects the neutral from external AC source, and neutral of the inverter output (AC panel loads) together when AC is applied to inverter input.

GFI

AC HOT IN

 

AC NEUTRAL IN

GFI’s will

EARTH GROUND

nuisance trip

 

with multiple

CHASSIS GROUND

Neutral-to-

 

Ground bonds

 

 

AC NEUTRAL OUT

RY1

AC HOT OUT

AC PANEL

 

Another NEUTRAL-

(RV/Marine)

TO-GROUND

HOT

NEUTRAL

“BOND” is

incorrectly provided

 

 

in the AC panel.

 

The neutral

 

conductor should

 

 

 

 

not be connected to

GROUND

 

the equipment

 

grounding

 

 

 

 

conductors or

 

 

enclosures.

Figure 14, Neutral-To-Ground Bond Switching: Neutral Bonded To Ground

Page

28

2001 Xantrex Technology, Inc.

Telephone: 360/435-8826

SW Series Inverter/Charger

5916 - 195th Street N. E.

Fax: 360/435-2229

Part No. 2031-5

Arlington, WA 98223

www.traceengineering.com

Rev. C: February 2001

Page 36
Image 36
Xantrex Technology 120 VAC/60 Ac Source, Neutral-To-Ground Bond Switching Neutral Bonded To Ground, Installation, Page