Advanced Settings

FSPM 00: Status

L2 Amps

0.0A

Batt Voltage

12.8V

Circuit Status

 

 

 

Config

 

 

Enter

Func

 

1

To enable the selection of Advanced Settings, press the Enter, Up, and Down arrow buttons (1) simultaneously from the Device Status screen.

FSPM 00: Status

Batt Voltage

12.8V

Circuit Status

Config

Advanced Settings

EnterFunc

32

Once the Advanced Settings item appears from the Device Status screen, scroll down (2) until Advanced Settings is highlighted then, Press Enter (3) to bring up the Advanced Settings screen.

FSPM 00: Advanced Settings

 

 

 

BKR Derating

 

[Enabled]

GEN BKR Rating

 

[30.0A]

GEN Warmup Delay

[0sec]

Connect Seq Delay [10sec]

EnterFunc

4

To activate a specific Advanced Settings item, move through each item using the Up and Down buttons (4). When a selection is made, press the Enter button to activate the highlighted advanced setting.

Complete list of Advanced Settings items.

FSPM 00: Advanced Settings

BKR Derating

[Enabled]

GEN BKR Rating

[30.0A]

GEN Warmup Delay

[0sec]

Connect Seq Delay

[10sec]

AC Disq Priority

[2]

Nom DC Voltage

[12.0V]

Circuit1

 

Circuit2

 

Circuit3

 

Circuit4

 

Circuit5

 

Circuit6

 

Circuit7

 

Circuit8

 

Circuit9

 

Circuit10

 

Figure 10 Freedom Sequence Advanced Settings Screen

List of advanced settings include:

1.BKR Derating – sets the breaker derating to 80% or 100%.

2.GEN BKR Rating – sets the breaker rating for the generator.

3.GEN Warmup Delay – sets the generator warmup delay from 0 to 240 seconds.

4.Connect Sequence Delay – sets the reconnect delay from 4 to 60 seconds.

5.AC Disq Priority– sets a priority number from 1 (high) to 10 (low).

6.Nom DC Voltage – sets a DC voltage rating of 12.0 V or 24.0 V.

7.Circuit1 to Circuit10 – changes circuit level settings.

Six-circuit Freedom Sequence model (PN: 809-0912): AC circuits are from Circuit1 to Circuit6 and the DC circuits are from Circuit7 to Circuit10.

Four-circuit Freedom Sequence model (PN: 809-0913): AC circuits are from Circuit1 to Circuit4 and the DC circuits are from

Circuit5 to Circuit8.

 

 