Range Selection

The instrument has three ranges: 35V/3A, 15V/5A and 35V/500mA. The selected range is shown by an illuminated indicator below the appropriate legend at the top right-hand side of the instrument; when the 35V/500mA range is selected the indicator legend is mA to emphasise that the current meter now shows milliamps not amps.

To change range press SHIFT followed by RANGE or RANGE ; each press of RANGE selects the next range to the left; each press of RANGE selects the next range to the right; there is no 'wrap-round'. When the range is changed the indicator that represents the new range and the OK key both flash; pressing OK sets the new range. To exit without changing range press ESCAPE. Pressing any other key whilst in range change mode causes the warning buzzer to beep twice; no other action is taken. If OK is not pressed within 10 seconds of the last range change key press the range selection remains unchanged.

The range can only be changed when the output is off. Pressing the RANGE or RANGE keys with the output on will cause the output ON/OFF key (as well as the OK key) to flash. The output may be turned off with the ON/OFF key and the range then changed by pressing OK, or OK may be pressed directly in which case the output is automatically turned off and the range then changed.

If a range change causes a voltage or current limit setting to exceed the corresponding maximum of the new range the range change is accepted but the setting is made equal to the maximum of the new range.

Note that the OVP setting is not changed when the range is changed (e.g. an OVP setting of 38V remains valid on the 15V range); it is left to the user to independently change the OVP setting if required.

Connection to the Load

The load should be connected to the positive (red) and negative(black) OUTPUT terminals. Both are fully floating and either can be connected to ground.

Remote Sensing

The instrument has a very low output impedance, but this is inevitably increased by the resistance of the connecting leads. At high currents this can result in significant differences between the indicated source voltage and the actual load voltage (two 20mconnecting leads will drop 0·2V at 5 Amps, for instance). This problem can be minimised by using short, thick, connecting leads, but where necessary it can be completely overcome by using the remote sense capability.

This requires the sense terminals to be connected to the output at the load instead of at the source; insert wires into the spring-loaded REMOTE SENSE terminals and connect directly to the load.

Select remote sense by pressing SHIFT, SENSE; the OK key flashes and the lamp above the remote sense terminals lights to show that remote sense will be selected when OK is pressed. Press OK to confirm; press ESCAPE to exit without changing state. Remote sense is turned off by pressing SHIFT, SENSE again; the OK key flashes and the remote sense lamp goes off to indicate that local sense will be restored when OK is pressed. Press OK to confirm; press ESCAPE to exit without changing state.

To avoid instability and transient response problems, care must be taken to ensure good coupling between each output and sense lead. This can be done either by twisting the leads together or by using coaxially screened cable (sense through the inner). An electrolytic capacitor directly across the load connection point may also be beneficial.

The voltage drop in each output lead must not exceed 0·5 Volts.

The XDL 35-5TP has rear panel output and sense terminals, appropriate for when the instrument is used in a rack. The rear panel sense terminals should always be used with the rear panel output connections.

19

Page 20
Image 20
Xantrex Technology XDL 35-5TP manual Range Selection, Connection to the Load, Remote Sensing

XDL 35-5T, XDL 35-5TP specifications

Xantrex Technology has established itself as a leader in the power conversion industry, and their XDL series, specifically the XDL 35-5TP and XDL 35-5T, exemplifies their commitment to innovation and reliability in power management solutions. Designed for a variety of applications, these models offer high performance and efficiency, catering to both professional and recreational users.

The XDL 35-5TP is recognized for its robust design and versatility, suitable for various applications, including battery charging, powering electronic devices, and supporting other power equipment. It features a maximum output of 35 amps and can deliver a continuous power supply sufficient for multiple devices. The integrated temperature monitoring ensures optimal performance and longevity, while the built-in safety features protect against overloads and short circuits.

One of the standout features of the XDL 35-5TP is its advanced microprocessor control, which allows for smart charging profiles. This technology not only increases efficiency but also extends battery life by managing the charging cycle meticulously. Users can take advantage of adjustable charging voltage settings, making the XDL 35-5TP compatible with various battery types, including lead-acid and lithium-ion.

The XDL 35-5T, on the other hand, while sharing many of the core features of the TP model, focuses more on size and weight optimization without compromising power delivery. This makes it an excellent choice for mobile users and those with limited installation space. Both models boast a durable design, suitable for harsh environmental conditions, ensuring reliability whether used in marine, automotive, or off-grid applications.

In terms of connectivity, the XDL series includes multiple output options, allowing users to connect various devices seamlessly. The front-mounted display panel gives real-time feedback on battery status and system performance, enabling informed management of power resources. Additionally, both models are engineered to minimize electromagnetic interference, ensuring operation without disrupting other electronic systems.

Overall, the Xantrex XDL 35-5TP and XDL 35-5T represent cutting-edge solutions in power technology, combining innovative features with practical usability. Their high efficiency, safety protocols, and flexibility in applications make them an excellent choice for users seeking reliable power solutions in diverse settings. Whether for recreational vehicles, boats, or emergency backup, the XDL series stands out as a testament to Xantrex's commitment to quality and performance in power conversion technology.