Routine calibration is carried out without opening the instrument.

Allow 10 minute warm-up before commencing calibration.

Equipment Required

A 5.5 digit multimeter with better than 0.02% accuracy on dc volts and better than 0.12% accuracy on dc current (to 5A); alternatively use a precision shunt for current measurement.

Calibration

Assign CONTROL to Output 1. To enter calibration press SHIFT, #, 99. If the instrument is a long way out of calibration, the default calibration values should be loaded first by pressing SHIFT, #,

91.Pressing ESCAPE at anytime will abort the calibration procedure and revert to the stored calibration values.

Having entered calibration mode, follow the table below. To increment to the next step press OK. The calibration must be done in sequence. At the end of calibration press OK to store the calibration. The instrument automatically sets the range and settings at each step.

Use the spin-wheel to adjust calibration; holding down the JOG SET OFF key will give x100 increments to speed up calibration. Pressing SHIFT will show the calibration value.

Repeat for Output 2.

Step/Range

Settings

Adjust for:-

Load

Detail

1, 35V 3A

0.01V 3A

10mV ± 0.5mV

DVM

o/p 0V

2, 35V 3A

0.01V 3A

0.010V on display

DVM

V readback zero

3, 35V 3A

35V 3A

35V ± 0.5mV

DVM

o/p V span

4, 35V 3A

35V 3A

35.000 on display

DVM

V readback span

5, 35V 3A

0.01V 3A

10mV ± 0.5mV

DVM

o/p 0V

6, 35V 3A

35V 3A

35V ± 0.5mV

DVM

o/p V span

7, 35V 3A

2V 0.001A

1mA ± 0.5mA

milli-ammeter

o/p A offset

8, 35V 3A

2V 0.001A

0.001 on display

milli-ammeter

A readback zero

9, 35V 500mA

2V 0.1mA

0.1mA ± 0.05mA

milli-ammeter

o/p mA offset

10, 35V 500mA

2V 0.1mA

flashing 0.0/0.1 on display

milli-ammeter

mA readback zero

 

 

 

change load

 

11, 15V 5A

2V 4A

4A ± 0.5mA

ammeter

o/p A span

12, 15V 5A

2V 4A

4.000 on display

ammeter

A readback span

13, 15V 5A

2V 4.1A

4.100 on display

ammeter

A readback 13bit

14, 35V 500mA

2V 400mA

400mA ± 0.05mA

ammeter

o/p mA span

15, 35V 500mA

2V 400mA

400.0 on display

ammeter

mA readback span

16, 35V 500mA

2V 410mA

410.0 on display

ammeter

mA readback 13bit

Page 42
Image 42
Xantrex Technology XDL 35-5TP manual Calibration, Equipment Required, Step/Range Settings Adjust for Load Detail, Dvm

XDL 35-5T, XDL 35-5TP specifications

Xantrex Technology has established itself as a leader in the power conversion industry, and their XDL series, specifically the XDL 35-5TP and XDL 35-5T, exemplifies their commitment to innovation and reliability in power management solutions. Designed for a variety of applications, these models offer high performance and efficiency, catering to both professional and recreational users.

The XDL 35-5TP is recognized for its robust design and versatility, suitable for various applications, including battery charging, powering electronic devices, and supporting other power equipment. It features a maximum output of 35 amps and can deliver a continuous power supply sufficient for multiple devices. The integrated temperature monitoring ensures optimal performance and longevity, while the built-in safety features protect against overloads and short circuits.

One of the standout features of the XDL 35-5TP is its advanced microprocessor control, which allows for smart charging profiles. This technology not only increases efficiency but also extends battery life by managing the charging cycle meticulously. Users can take advantage of adjustable charging voltage settings, making the XDL 35-5TP compatible with various battery types, including lead-acid and lithium-ion.

The XDL 35-5T, on the other hand, while sharing many of the core features of the TP model, focuses more on size and weight optimization without compromising power delivery. This makes it an excellent choice for mobile users and those with limited installation space. Both models boast a durable design, suitable for harsh environmental conditions, ensuring reliability whether used in marine, automotive, or off-grid applications.

In terms of connectivity, the XDL series includes multiple output options, allowing users to connect various devices seamlessly. The front-mounted display panel gives real-time feedback on battery status and system performance, enabling informed management of power resources. Additionally, both models are engineered to minimize electromagnetic interference, ensuring operation without disrupting other electronic systems.

Overall, the Xantrex XDL 35-5TP and XDL 35-5T represent cutting-edge solutions in power technology, combining innovative features with practical usability. Their high efficiency, safety protocols, and flexibility in applications make them an excellent choice for users seeking reliable power solutions in diverse settings. Whether for recreational vehicles, boats, or emergency backup, the XDL series stands out as a testament to Xantrex's commitment to quality and performance in power conversion technology.