56
Programming
Status Reporting Commands
Status Reporting Commands
See also Status Reporting on page 68.
Note • All status commands are immediate, that is they pass the print queue and is answered directly.
ESC ENQ 1 |
| Status Enquiry |
1B 05 01 | hex | |
27 5 1 | decimal |
|
A status enquiry results in response ACK (06h) if all sensors are clear, but NAK (15h) + code if one or more sensors report fault condition.
|
|
| Figure 19 • Error Codes |
|
|
|
|
Error code | Meaning | ||
|
|
|
|
ACK | OK (printer is operable) | ||
|
|
|
|
NAK 1 | Paper left in presenter module. Attempt to clear the paper path failed.* | ||
|
|
|
|
NAK 2 | Cutter jammed | ||
|
|
|
|
NAK 3 | Out of paper | ||
|
|
|
|
NAK 4 | Printhead lifted | ||
|
|
|
|
NAK 5 | |||
|
| printed. Paper might be wound around the platen or, in some way, has | |
|
| been forced above the presenter module. | |
|
|
|
|
NAK 6 | Temperature error. The printhead temperature has exceeded the 60 °C | ||
|
| maximum limit. | |
|
|
|
|
NAK 7 | Presenter not running (no feedback from code wheel) | ||
|
|
|
|
NAK 0A | Black mark not found | ||
|
|
|
|
NAK 0B | Black mark calibration error | ||
|
|
|
|
NAK 0C | Index error | ||
|
|
|
|
NAK 0D | Checksum error | ||
|
|
|
|
NAK 0E | Wrong firmware type | ||
|
|
|
|
NAK 0F | Firmware cannot start because no firmware is loaded or firmware | ||
|
| checksum is wrong. | |
|
|
|
|
NAK 10 | Waste bin timed out. If the customer doesn’t take the paper and the | ||
|
| printer clears the presenter due to a timeout, the pending error bit is set | |
|
| and error code NAK 16 is reported. | |
|
|
|
|
NAK FF | Undefined error | ||
|
|
|
|
|
|
|
|
*. From firmware version 3.00, the printer will retry three times (cut + clear presenter), when failing to clear the presenter.
| TTP 7030™ Technical Manual | 10/05/2009 |