104

Maintenance

Firmware

Firmware

The firmware is stored in flash-PROM on the control board. A replacement control board may not contain the same firmware version that you are currently using, so if you replace the control board for some reason, upgrade it to the firmware version you want to use.

Please visit our web site http://www.zebra.com for the most current firmware versions.

Loading

Note • We recommend you to design your kiosk system so that remote upgrade of firmware is possible. If you need to upgrade firmware in the future, the kiosks can be spread over a vast area and upgrade can become very expensive.

Download the most current firmware version from the Zebra web site http://www.zebra.com. There you will also find the Toolbox utility program (Windows™ software) facilitating the loading of the firmware into the printer.

Are you using a Windows environment to load the firmware?

If…

Then…

 

 

 

No

a.

Send <ESC><NUL> (1BH 00H) to the printer.

 

b.

Wait 0.5 seconds.

 

c.

Send the firmware file to the printer.

 

d. Wait until the printer buzzes to confirm that the loading is complete (the

 

 

presenter motor runs for a second).

 

 

Yes

The loader program contains a help file with detailed instructions on how to

 

load the firmware into the printer.

 

 

 

Important • The loading and burning can take up to one minute. Do not abort before one minute by turning OFF the power to the printer. Doing so may leave the printer in a state where new firmware cannot be loaded. If this occurs, please return the printer to a Zebra authorized service provider.

Functions and features are being added from time to time, affecting the firmware in the printer. The following table lists the changes of general interest. The firmware number is divided into two sections, the header and the version, separated by a dash.

Printer

Barcode support

Firmware header

 

 

 

TTP 7030

1D barcodes

1856-xxx

 

 

 

TTP 7030

2D PDF-417

1860-xxx

 

 

 

A printer can only be updated with firmware that has the same header as the original number. The -xxx indicates the firmware version; for example, 330 means firmware version 3.30.

Note • Specification subject to changes without notice.

P1003636-002

TTP 7030™ Technical Manual

10/05/2009

Page 104
Image 104
Zebra Technologies TTP 7030 technical manual Firmware