12.4.10 Uploading Configuration File Via Console Port

ExpWave 240B Secure Outdoor Ethernet Radio Link

After the firmware upload process has completed, the ExpWave will automatically restart.

12.4.10 Uploading Configuration File Via Console Port

Step 1. Select 2 from Menu 24.7 – System Maintenance – Upload Firmware to display Menu 24.7.2 - System Maintenance - Upload System Configuration File. Follow the instructions as shown in the next screen.

Menu 24.7.2 - System Maintenance - Upload System Configuration File

To upload system configuration file:

1.Enter "y" at the prompt below to go into debug mode.

2.Enter "atlc" after "Enter Debug Mode" message.

3.Wait for "Starting XMODEM upload" message before activating Xmodem upload on your terminal.

4.After successful firmware upload, enter "atgo" to restart the system.

Warning:

1.Proceeding with the upload will erase the current configuration file.

2.The system’s console port speed (Menu 24.2.2) may change when it is restarted; please adjust your terminal's speed accordingly. The password may change (menu 23), also.

3.When uploading the DEFAULT configuration file, the console port speed will be reset to 9600 bps and the password to "1234".

Do You Wish To Proceed:(Y/N)

Figure 12-18 Menu 24.7.2 as seen using the Console Port

Step 2. After the "Starting Xmodem upload" message appears, activate the Xmodem protocol on your computer. Follow the procedure as shown previously for the HyperTerminal program. The procedure for other serial communications programs should be similar.

Step 3. Enter “atgo” to restart the ExpWave.

12.4.11Example Xmodem Configuration Upload Using HyperTerminal

Click Transfer, then Send File to display the following screen.

Type the configuration file’s location, or click Browse to search for it.

Choose the Xmodem protocol.

Then click Send.

Figure 12-19 Example Xmodem Upload

After the configuration upload process has completed, restart the ExpWave by entering “atgo”.

12-10

Firmware & Configuration File Maintenance

Page 84
Image 84
ZyXEL Communications Uploading Configuration File Via Console Port, ExpWave 240B Secure Outdoor Ethernet Radio Link