Prestige 310 Broadband Sharing Gateway

Menu 24 - System Maintenance

1.System Status

2.System Information and Console Port Speed

3.Log and Trace

4.Diagnostic

5.Backup Configuration

6.Restore Configuration

7.Upload Firmware

8.Command Interpreter Mode

9.Call Control

10.Time and Date Setting

11.Remote Management Setup

Enter Menu Selection Number:

Figure 11-6 Menu 24 — System Maintenance

Then enter 10 to go to Menu 24.10 — System Maintenance — Time and Date Setting to update the time and date settings of your Prestige as shown in the following screen.

Menu 24.10 - System Maintenance - Time and Date Setting

Use Time

Server when Bootup= None

 

 

 

Time Server IP Address= N/A

 

 

 

Current Time:

00 :

00 :

00

New Time

(hh:mm:ss):

11 :

23 :

16

Current Date:

2000

- 01

- 01

New Date

(yyyy-mm-dd):

2001

- 03

- 01

Time Zone= GMT

 

 

 

Daylight

Saving= No

 

 

 

Start Date (mm-dd):

 

01 – 01

End Date

(mm_dd):

 

01 – 01

Press ENTER to Confirm or ESC to Cancel:

Figure 11-7 Menu 24.10 System Maintenance — Time and Date Setting

 

Table 11-3 Time and Date Setting Fields

 

 

FIELD

DESCRIPTION

Use Time Server

Enter the time service protocol that your time server sends when you turn on the

when Bootup

Prestige. Not all time servers support all protocols, so you may have to check with

 

your ISP/network administrator or use trial and error to find a protocol that works.

 

The main differences between them are the format.

 

Daytime (RFC 867) format is day/month/year/time zone of the server.

 

 

System Maintenance and Information