Prestige 645 ADSL Internet Access Router

9.4SNMP Traps

The Prestige will send traps to the SNMP manager when any one of the following events occurs:

Table 9-2 SNMP Traps

TRAP #

TRAP NAME

DESCRIPTION

1

coldStart (defined in RFC-1215)

A trap is sent after booting (power on).

 

 

 

2

warmStart (defined in RFC-1215)

A trap is sent after booting (software reboot).

 

 

 

3

linkUp (defined in RFC-1215)

A trap is sent with the port number.

 

 

 

4

authenticationFailure (defined in

A trap is sent to the manager when receiving any SNMP

 

RFC-1215)

get or set requirements with wrong community (password).

 

 

 

5

whyReboot (defined in ZYXEL-

A trap is sent with the reason of restart before rebooting

 

MIB)

when the system is going to restart (warmstart).

5a

For intentional reboot :

A trap is sent with the message "System reboot by user!" if

 

 

reboot is done intentionally, (e.g. download new files, CI

 

 

command "sys reboot", etc.).

5b

For fatal error :

A trap is sent with the message of the fatal code if the

 

 

system reboots because of fatal errors.

6

linkDown (defined in RFC-1215)

A trap is sent with the port number when any of the links

 

 

are down. See the following table.

 

 

 

9-4

SNMP Configuration