Dimension
STEPS | CORRECTIVE ACTION |
1Check the connection between the switch and your Ethernet device(s).
2Check that the port is enabled.
3Make sure you’re using the correct table type and that the distance between the switch and the device does not exceed 100 meters.
19.1.4 The FD/COL LED
Use this LED to check the duplex mode of the attached Ethernet device.TableSTEPS | CORRECTIVE ACTION |
1The Ethernet device is connected at
2The Ethernet device is connected at
3Make sure you have the correct speed and flow control enabled for each port. Refer to the Port Control chapter.
3This LED blinks if packet collisions are occurring. Collisions are normal, but if the FD/COL LED blinks very frequently, you may need to segment your network.
19.2 Console Port
I cannot access the switch through the console port.TableSTEPS | CORRECTIVE ACTION | |
|
|
|
1 | Check to see if the switch is connected to your computer using the | |
|
|
|
2 | Check to see if the communications program | Emulation: auto detect |
| is configured correctly. Set the | Baud Rate: 9600 bps |
| communication parameters as stated here. | No Parity, 8 data bits, 1 stop bit |
|
| |
|
| Flow Control: None |
|
|
|
Troubleshooting |