Prestige 334W User’s Guide
31.4 SNMP Traps
The Prestige will send traps to the SNMP manager when any one of the following events occurs:
TableTRAP # | TRAP NAME | DESCRIPTION |
|
|
|
1 | coldStart (defined in | A trap is sent after booting (power on). |
|
|
|
2 | warmStart (defined in | A trap is sent after booting (software reboot). |
|
|
|
3 | linkDown (defined in | A trap is sent with the port number when any of the links |
|
| are down. See the following table. |
|
|
|
4 | linkUp (defined in | A trap is sent with the port number. |
|
|
|
5 | authenticationFailure (defined in | A trap is sent to the manager when receiving any SNMP |
| gets or sets requirements with wrong community | |
|
| (password). |
|
|
|
6 | whyReboot (defined in ZYXEL- | A trap is sent with the reason of restart before rebooting |
| MIB) | when the system is going to restart (warm start). |
|
|
|
6a | For intentional reboot : | A trap is sent with the message "System reboot by user!" if |
|
| reboot is done intentionally, (for example, download new |
|
| files, CI command "sys reboot", etc.). |
|
|
|
The port number is its interface index under the interface group.
TablePORT | PVC (PERMANENT VIRTUAL CIRCUIT) |
|
|
1 | Ethernet LAN |
|
|
2 | 1 |
|
|
3 | 2 |
|
|
… | … |
|
|
13 | 12 |
|
|
14 | xDSL |
|
|
SNMP Configuration |