Quadra-Fire 839-1440, 839-1460, 839-1390 For Your Safety Read Before Lighting, Lighting Appliance

Page 39

C. Lighting Appliance

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may

result causing property damage, personal injury or loss of life

A.This appliance has a pilot that must be lit manually. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING, smell around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

*Do not try to light any appliance.

*Do not touch any electric switch, do not use any phone in your building.

*Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

*If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

 

LIGHTING INSTRUCTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

STOP! Read the safety information above on this label.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Set the thermostat to the lowest setting (if applicable) and turn off

 

 

 

 

 

 

 

 

 

 

the switch at the control panel.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

Disconnect the power from the appliance.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

Open the door of the appliance. May need to remove face/front first.

 

 

 

 

5.

Push in gas control knob slightly and turn clockwise

to the "OFF"

 

 

 

position. Do not force.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.Wait five (5) minutes to clear out any gas. Smell for gas, including near the floor. If you smell gas, STOP! Follow "B" of the safety information above. If you don't smell gas go to the next step.

7.Push gas control knob in and turn counterclockwise to the pilot position. NOTE: Knob cannot be turned unless knob is pushed in slightly. Do not force.

8.PIEZO IGNITER: Press down on the gas control knob in pilot position and simultaneously press the piezo igniter.

(This may take many repetitions for lighting.)

ELECTRONIC IGNITER: If the unit is equipped with an electronic igniter it should begin sparking right away.

9.The pilot should be visible through the door opening.

10.After the pilot is lit, continue holding control knob down for approximately

30 seconds. Release the knob and it will pop back up. Pilot should remain lit.

MILLIVOLT

PILOT HOOD

THERMOCOUPLE

If it goes out, repeat steps 7 through 9.

GENERATOR

* If the knob does not pop up when released, stop and immediately call your

 

 

service technician or gas supplier.

 

 

* If the pilot will not stay lit after several tries, turn the gas control knob

 

 

clockwise

to "OFF" and call your service technician or gas supplier.

 

 

11. Reinstall door and face. Wait five minutes to allow pilot flame to stabilize and establish proper draft.

12.Push down and turn gas control knob counterclockwise to "ON".

13.Push burner rocker switch on the control panel to "ON". If thermostat is to be used, leave switch in "OFF" position and set the thermostat to desired setting.

14.Reconnect electrical power to appliance.

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to lowest setting.

2.Turn off all electric power to the appliance if service is to be performed.

3.Push in gas control knob slightly and turn clockwise to "OFF" position.

January 28, 2008

Quadra-Fire · Sapphire · 250-7233E

Page 39

Image 39
Contents Do not Discard this Manual What to do if you smell gasSolitaire Front Quartet FrontQuadra-Fire · Sapphire · 250-7233F January 28 Table of Contents 1Listing and Code Approvals Requirements for the Commonwealth of Massachusetts BELOW. Keep Clear of ALL ObstructionsManufacturer Requirements Tools and Supplies Needed Getting StartedAppliance Location and Clearances Selecting Appliance LocationClearances Vent Termination Minimum Clearances 4Termination LocationsAlcove Applications Measuring Standards Vent InformationVenting Components Use of ElbowsTOP Vent Graph Rear Venting with Vertical Rise How to Use the Vent Graph Venting GuidelinesStep Type B Rear Installations for Use with Rear Vent KitType a Up & Out Installations for Top Vent Configurations Horizontal TerminationElbow in Corner Installation 203mm 178mm 152mm Direct Vent Pipe Vertical TerminationStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Ft m Existing Masonry ChimneyCap Flex Liner Flex Coupler Sheet Metal Screws Gas Information Fuel ConversionsConverting to LP Gas Propane Natural GAS Pressure Gas PressuresCheck for GAS Leaks Gas ConnectionWire Size Max. Length Recommendation for WireConnecting to the Appliance Standing Pilot Ignition System WiringThermopile GAS Pilot Ignitor Thermocouple At the TOP of the appliance, with exceptions noted Appliance SetupRemove Shipping Materials Top and Rear Vent ConversionReplace Burner Orifice for Horizontal Vent Configurations Grille Cover Plate Installation Accessories059 53 DMS 096 41DMS Quartet Door Alignment Front InstallationFronts are shipped attached to the face For Both Quartet and Solitaire FrontsHearth Legs Installation Positioning the LogsQty Description Blower from front Glass Door Assembly InstallationBlower Installation Mineral WoolPage Blower 26 Blower Wiring DiagramMake adjustment Damper AdjustmentShutter Adjustment For TOP or Rear Vent InstallationsOperating Instructions Before Lighting ApplianceControls Lighting Appliance For Your Safety Read Before LightingFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Symptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing ApplianceNecessary. USE Caution When CLEANING/HANDLING Ceramic Burner Maintenance Tasks InspectDate of Service Performed By Description of Service Service and Maintenance LogReference Materials Appliance Dimension DiagramVent Components Diagram Miscellaneous Vent Components ListItem # Description RD. Service Parts ListRD. Service Parts cont’d Service Parts cont’d Cast Parts Individual Pieces AccessoriesWarranty Policy This page Intentionally Left Blank January 28 Quadra-Fire · Sapphire · 250-7233E Sapphire Contact InformationDealer Telephone