11 Maintaining and Servicing Appliance

Although the frequency of your appliance servicing and maintenance will depend on use and the type of installation, a qualified service technician should perform an appliance check-up at the beginning of each heating season.

WARNING

Risk of injury or property damage.

Before servicing:

Turn off gas.

Turn off electricity to appliance.

Ensure appliance is completely cooled.

After servicing:

Replace front and glass, if removed.

Reseal and reinstall any venting removed for servicing.

WARNING

Annual inspection by qualified technician recommended.

Check:

Condition of glass, glass assembly and glass seal.

Obstructions of combustion and ventilation air.

Obstructions of termination cap.

Burner ignition and operation.

Burner air shutter adjustment

Gas connections and fittings.

Clean:

Glass

Air passageways, grilles, control compartment

Burner, burner ports. USE CAUTION WHEN CLEANING/

HANDLING CERAMIC BURNER.

Risk of:

Fire

Delayed ignition or explosion

Exposure to combustion fumes

Odors

WARNING

Inspect external vent cap regularly.

Ensure no debris blocks cap.

Combustible materials blocking cap may ignite.

Restricted air flow affects burner operation.

CAUTION

Handle glass assembly with care.

NOTE: Clean glass after initial 3-4 hours operation. Longer operation without cleaning glass may cause a permanent white film on glass.

When cleaning glass door:

Avoid striking, scratching or slamming glass.

Do NOT use abrasive cleaners.

Use a hard water deposit glass cleaner on white film.

Do NOT clean glass when hot.

Turn off appliance after 3-4 hours of operation and ALLOW TO COOL.

Remove and clean glass assembly.

Replace glass assembly and operate appliance for additional 12 hours.

Refer to maintenance instructions.

January 28, 2008

Quadra-Fire · Sapphire · 250-7233E

Page 43

Image 43
Contents Do not Discard this Manual What to do if you smell gasSolitaire Front Quartet FrontQuadra-Fire · Sapphire · 250-7233F January 28 Table of Contents 1Listing and Code Approvals BELOW. Keep Clear of ALL Obstructions Requirements for the Commonwealth of MassachusettsManufacturer Requirements Tools and Supplies Needed Getting StartedSelecting Appliance Location Appliance Location and ClearancesClearances Vent Termination Minimum Clearances 4Termination LocationsAlcove Applications Measuring Standards Vent InformationVenting Components Use of ElbowsTOP Vent Graph Rear Venting with Vertical Rise How to Use the Vent Graph Venting GuidelinesStep Type B Rear Installations for Use with Rear Vent KitType a Up & Out Installations for Top Vent Configurations Horizontal TerminationElbow in Corner Installation 203mm 178mm 152mm Direct Vent Pipe Vertical TerminationStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Ft m Existing Masonry ChimneyCap Flex Liner Flex Coupler Sheet Metal Screws Fuel Conversions Gas InformationConverting to LP Gas Propane Natural GAS Pressure Gas PressuresCheck for GAS Leaks Gas ConnectionWire Size Max. Length Recommendation for WireConnecting to the Appliance Standing Pilot Ignition System WiringThermopile GAS Pilot Ignitor Thermocouple At the TOP of the appliance, with exceptions noted Appliance SetupRemove Shipping Materials Top and Rear Vent ConversionReplace Burner Orifice for Horizontal Vent Configurations Accessories Grille Cover Plate Installation059 53 DMS 096 41DMS Quartet Door Alignment Front InstallationFronts are shipped attached to the face For Both Quartet and Solitaire FrontsPositioning the Logs Hearth Legs InstallationQty Description Blower from front Glass Door Assembly InstallationBlower Installation Mineral WoolPage Blower 26 Blower Wiring DiagramMake adjustment Damper AdjustmentShutter Adjustment For TOP or Rear Vent InstallationsBefore Lighting Appliance Operating InstructionsControls Lighting Appliance For Your Safety Read Before LightingInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Symptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing ApplianceNecessary. USE Caution When CLEANING/HANDLING Ceramic Burner Maintenance Tasks InspectDate of Service Performed By Description of Service Service and Maintenance LogReference Materials Appliance Dimension DiagramVent Components Diagram Miscellaneous Vent Components ListItem # Description RD. Service Parts ListRD. Service Parts cont’d Service Parts cont’d Cast Parts Individual Pieces AccessoriesWarranty Policy This page Intentionally Left Blank January 28 Quadra-Fire · Sapphire · 250-7233E Contact Information SapphireDealer Telephone