Quadra-Fire 839-1390, 839-1460, SAPPH-D-CWL, SAPPH-D-CSB, 839-1440 Vent Components Diagram

Page 47

B. Vent Components Diagram

 

 

 

6-3/8 in.

 

 

 

6-1/2 in.

 

(162mm)

 

 

 

 

 

 

 

(165mm)

 

 

 

 

9-1/4 in.

 

 

 

 

 

(235mm)

 

 

 

6-1/2 in.

 

 

 

 

 

 

 

 

6-3/8 in.

 

(165mm)

9-5/8 in.

 

 

 

 

(244mm)

 

6-5/8 in.

(162mm)

 

 

 

 

(168mm)

 

 

 

 

 

SL-45D

 

 

 

 

 

 

6-5/8 in.

 

 

 

 

 

(168mm)

 

9-5/8 in.

 

 

 

SL-90D

 

 

 

(244mm)

17-24 in.

 

 

6-1/2 in.

 

 

(432-610mm)

 

 

(165mm)

 

 

 

11-3/4 in.

 

 

 

 

 

(298mm)

5-3/4 in.

 

 

 

 

 

 

 

 

 

 

(146mm)

 

 

 

SL-17/24D

 

 

6-5/8 in.

 

SL-12D

 

(168mm)

 

(SL17-24D)

SL-06D

 

 

 

 

 

 

 

 

 

 

47-3/4 in.

 

 

 

 

 

(1213mm)

 

 

 

35-3/4 in.

 

 

 

 

 

(908mm)

 

 

 

 

23-3/4 in.

 

 

 

 

 

(603mm)

 

 

 

 

12-17 in.

 

 

 

 

 

(305-432mm)

 

 

 

 

8-3/4 in.

 

 

 

 

 

(222mm)

 

 

 

 

 

SL-09D

SL-12/17D

SL-24D

SL-36D

SL-48D

 

(SL-12-17D)

 

 

 

 

 

4 in. (102 mm) inner pipe 6-5/8 in. (168 mm) outer pipe

 

Figure 12.2 SL-D Series Vent Components

 

 

 

 

January 28, 2008

Quadra-Fire · Sapphire · 250-7233E

 

Page 47

Image 47
Contents Do not Discard this Manual What to do if you smell gasSolitaire Front Quartet FrontQuadra-Fire · Sapphire · 250-7233F January 28 Table of Contents 1Listing and Code Approvals Manufacturer Requirements Requirements for the Commonwealth of MassachusettsBELOW. Keep Clear of ALL Obstructions Tools and Supplies Needed Getting StartedClearances Appliance Location and ClearancesSelecting Appliance Location Vent Termination Minimum Clearances 4Termination LocationsAlcove Applications Measuring Standards Vent InformationVenting Components Use of ElbowsTOP Vent Graph Rear Venting with Vertical Rise How to Use the Vent Graph Venting GuidelinesStep Type B Rear Installations for Use with Rear Vent KitType a Up & Out Installations for Top Vent Configurations Horizontal TerminationElbow in Corner Installation 203mm 178mm 152mm Direct Vent Pipe Vertical TerminationStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Ft m Existing Masonry ChimneyCap Flex Liner Flex Coupler Sheet Metal Screws Converting to LP Gas Gas InformationFuel Conversions Propane Natural GAS Pressure Gas PressuresCheck for GAS Leaks Gas ConnectionWire Size Max. Length Recommendation for WireConnecting to the Appliance Standing Pilot Ignition System WiringThermopile GAS Pilot Ignitor Thermocouple At the TOP of the appliance, with exceptions noted Appliance SetupRemove Shipping Materials Top and Rear Vent ConversionReplace Burner Orifice for Horizontal Vent Configurations 059 53 DMS 096 41DMS Grille Cover Plate InstallationAccessories Quartet Door Alignment Front InstallationFronts are shipped attached to the face For Both Quartet and Solitaire FrontsQty Description Hearth Legs InstallationPositioning the Logs Blower from front Glass Door Assembly InstallationBlower Installation Mineral WoolPage Blower 26 Blower Wiring DiagramMake adjustment Damper AdjustmentShutter Adjustment For TOP or Rear Vent InstallationsControls Operating InstructionsBefore Lighting Appliance Lighting Appliance For Your Safety Read Before LightingAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Symptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing ApplianceNecessary. USE Caution When CLEANING/HANDLING Ceramic Burner Maintenance Tasks InspectDate of Service Performed By Description of Service Service and Maintenance LogReference Materials Appliance Dimension DiagramVent Components Diagram Miscellaneous Vent Components ListItem # Description RD. Service Parts ListRD. Service Parts cont’d Service Parts cont’d Cast Parts Individual Pieces AccessoriesWarranty Policy This page Intentionally Left Blank January 28 Quadra-Fire · Sapphire · 250-7233E Dealer Telephone SapphireContact Information