Model

 

TS25

TS45

TS80

TS130

TS175

 

Standby output–

1500C Rise

 

 

 

 

 

 

(KVA/KW):

 

 

 

 

 

 

 

3 PH @ 480 Volt

 

 

 

 

 

 

25/20

48/38

81/65

134/107

175/140

 

3 PH @ 208/240 Volt

25/20

46/37

72/58

131/105

169/135

 

 

 

 

 

 

 

 

1 PH @ 240 Volt

18/18

27/27

45/45

70/70

80/80

 

Continuous Output–

 

 

 

 

 

 

1250C Rise (KVA/KW):

 

 

 

 

 

 

3 PH @ 480 Volt

 

 

 

 

 

 

23/18

44/35

75/60

121/97

169/135

 

3 PH @ 208/240 Volt

23/18

44/35

69/55

119/95

156/125

 

1 PH @ 240 Volt

 

 

 

 

 

G

18/18

25/25

43/43

66/66

75/75

E

Voltage – 3 PH Adjustable

208/220/240/

208/220/240/

208/220/240/

208/220/240/

208/220/240/

N

 

 

416/440/460/480

416/440/460/480

416/440/460/480

416/440/460/480

416/440/460/480

 

 

 

 

 

 

 

E

 

 

 

 

 

 

Voltage – 1 PH Adjustable

120/127/139/

120/127/139/

120/127/139/

120/127/139/

120/127/139/

R

 

 

240/254/277

240/254/277

240/254/277

240/254/277

240/254/277

A

Amperage (Continuous):

 

 

 

 

 

 

 

 

 

 

T

3 PH 480 Volt

 

 

 

 

 

 

 

27.1

52.6

90.2

145.8

203.0

O

3 PH 208 Volt

 

 

 

 

 

 

 

62.5

121.4

190.8

329.6

433.7

R

3 PH 240 Volt

 

 

 

 

 

 

 

54.1

105.3

165.4

285.7

375.9

 

1 PH 240 Volt/120 Volt

 

 

 

 

 

 

75.0/150.0

104.2/208.3

179.2/358.3

275/550

312.5/625.0

 

Receptacles:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120 Volt, 15 Amp GFCI

4

6

6

6

6

 

120/240 Volt, 50 Amp,

2

3

3

3

3

 

CS6369 Twistlock

 

 

 

 

 

 

Voltage Regulation 1/2%

 

 

 

 

 

 

1/2%

1/2%

1/2%

1/2%

1/2%

 

Power Factor – 3 Phase

 

 

 

 

 

 

0.8

0.8

0.8

.08

.08

 

Frequency

 

 

 

 

 

 

 

 

50 or 60 Hertz

50 or 60 Hertz

50 or 60 Hertz

50 or 60 Hertz

50 or 60 Hertz

 

Total Harmonic Distortion

 

 

 

 

 

 

<5%

<5%

<5%

<5%

<5%

 

Insulation

 

 

 

 

 

 

 

 

Class F

Class F

Class F

Class F

Class F

 

 

 

 

 

 

 

 

Engine Make/Model

Isuzu

Isuzu

John Deere

John Deere

John Deere

 

 

 

4LE

4BG1

TO4045T

TO6068

RG6081T

 

Design

 

 

 

 

 

 

 

 

Water Cooled

Water Cooled

Water Cooled

Water Cooled

Water Cooled

 

 

 

4 Cycle Diesel

4 Cycle Diesel

4 Cycle Diesel

4 Cycle Diesel

4 Cycle Diesel

 

Starting System

 

 

 

 

 

 

12 VDC

12 VDC

12 VDC

12 VDC

12 VDC

 

Displacement (cid)

 

 

 

 

 

 

133.0

264.2

276.0

414.0

498.0

 

Cylinders

 

 

 

 

 

 

 

 

4

4

4

6

6

 

HP @ Rated Speed

 

 

 

 

 

 

34.5

64.0

100.0

166.0

211.0

 

RPM

 

 

 

 

 

 

E

 

1800

1800

1800

1800

1800

Safety Shutdowns:

 

 

 

 

 

 

 

 

 

 

N

 

 

 

 

 

High Temperature

Std.

Std.

Std.

Std.

Std.

G

Low Oil

 

Std.

Std.

Std.

Std.

Std.

I

 

Overspeed

 

Std.

Std.

Std.

Std.

Std.

N

Overcrank

 

Std.

Std.

Std.

Std.

Std.

E

Fuel Capacity

 

 

 

 

 

 

 

50

80

80

160

160

 

Fuel Consumption (GPH):

 

 

 

 

 

 

 

 

 

 

 

 

1/2 Load

 

1.3

2.0

2.7

4.2

5.6

 

Full Load

 

2.0

3.4

4.9

8.1

10.5

 

Approx. Run Time (Hrs.):

 

 

 

 

 

 

 

 

 

 

 

 

1/2 Load

 

38

40

30

38

29

 

Full Load

 

25

24

16

20

15

 

Battery Recommendation Min. Cold

 

 

 

 

 

 

750

900

900

(2) 750

(2) 750

 

Cranking Amps

 

 

 

 

 

 

(Battery not included)

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions (L x W x H):

 

 

 

 

 

 

With Trailer

 

123” x 62” x 70”

139” x 60” x 81”

139” x 60” x 81”

163” x 66” x 94”

163” x 66” x 94”

 

Without Trailer

74” x 38” x 52”

84” x 38” x 61”

84” x 38” x 61”

108” x 42” x 74”

108” x 42” x 74”

 

Weight (Lbs.):

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Without Fuel

 

2265

3540

3848

5600

6200

 

Without Fuel & Trailer

1790

2829

3053

4610

5205

 

 

 

 

 

 

 

 

7

Image 10
Contents Baldor Generators Towables OPERATOR’S ManualPage Safety Warnings FORM# S-PSG-001-3 ```` for Gasoline or Diesel Powered Generator Sets ```` Page Forward \ISO9001\FORMS\SCSD0037.MSW Features & Specifications Page Switchable Connection Information Control Panel Operation Function Page Page Operation PRE-START Procedure Operation Starting Operation Cranking Control Troubleshooting Generator LOW VoltageHigh Voltage Fluctuating VoltageOverheating Generator Frame Produces Shock When Touched Mechanical NoiseTroubleshooting Engine Page Magnaplus Generator Table of Contents Specifications Parts List Single Bearing Unpacking and Handling SafetyReceiving and Storage StoragePrinciples of Operation PMG optionalNonlinear Loading InstallationParallel Operation Preparation for USEGenerator Mounting END Play TestingTorsional Vibration Wiring Connections Environmental ConsiderationsLOW WYE Connection Double Delta -- Single Phase Connection PRE-START Inspection OperationSTART-UP Maintenance Shutdown ProcedureTesting Drying WindingsGeneral ServiceDiode Testing Field FlashingBearing Replacement Bearing RemovalTroubleshooting Returned GoodsGenerator Produces no Voltage Generator Produces LOW VOLTAGE, no LoadGenerator Produces Fluctuating Voltage Generator Produces LOW Voltage When Load AppliedGenerator Produces High Voltage Generator is Overheating Generator Produces Mechanical NoiseSpecifications Parts List Single Bearing Parts List Dual Bearing Rules for Safe Trailer Operation Towing VehicleElectrical Trailer Wiring Towing Heavy Trailer LoadsSafety Checks Trailer Light KIT Wiring Instructions Trailer Light Mounting and ConnectionLimited Warranty Owner’s Responsibilities Page California Proposition 65 Warning