z Circuit overload protection must be provided in accordance with national electrical codes and local regulations.
z Check GFCI Receptacles monthly by using the ”Test” and ”Reset” buttons designed into them.
z Depending on your application it may be mandatory to ground or not ground this unit to earth ground. Comply with local electrical codes.
Inspect wiring frequently and replace frayed, broken or poor leads.
Have the electrical circuits serviced only by qualified technicians.
Disconnect all leads plugged into the unit Prior to working on it.
Always treat the electrical circuits as if they were energized.
z z z z
z Do not connect this unit to any building’s electrical system unless you utilize an approved transfer switch or the main service entrance switch has been disconnected and locked open.
SAFETY WARNINGS

```` FOR GASOLINE OR DIESEL POWERED GENERATOR SETS ````

zOperate the generator set on a level surface. If the generator set is tilted, fuel spillage may result.

zHandle fuel with care. It is highly flammable. Use only clean, properly marked and approved safety containers for refueling and storing fuel.

zStop the engine and allow it to cool before refueling.

zDo not overfill the fuel tank. Only fill the tank to within 1/2” of the top of the tank to allow space for fuel expansion.

zIf fuel is spilled, wipe it up carefully and wait until the fuel has dried before starting the engine.

zMake sure the fuel cap is properly closed after refueling.

zNever operate the generator set while smoking.

zNever operate the generator set near an open flame.

zNever store the generator set with fuel in the tank indoors or in an enclosed, poorly ventilated enclosure where fuel fumes may reach an open flame, electrical spark or pilot light as on a furnace, water heater, clothes dryer, etc.

zWhen transporting over long distances or rough roads, drain the fuel tank to prevent leakage and spillage.

Revised: 8/13/02

Page 3 of 4

FORM#: S–PSG–001–3

Effective: 2/27/98

3

C:\ISO9001\FORMS\SPSG0013.msw.bbk

 

 

Image 6
Contents Baldor Generators Towables OPERATOR’S ManualPage Safety Warnings FORM# S-PSG-001-3 ```` for Gasoline or Diesel Powered Generator Sets ```` Page Forward \ISO9001\FORMS\SCSD0037.MSW Features & Specifications Page Switchable Connection Information Control Panel Operation Function Page Page Operation PRE-START Procedure Operation Starting Operation Cranking Control Troubleshooting Generator LOW VoltageFluctuating Voltage High VoltageOverheating Generator Frame Produces Shock When Touched Mechanical NoiseTroubleshooting Engine Page Magnaplus Generator Table of Contents Specifications Parts List Single Bearing Unpacking and Handling SafetyReceiving and Storage StoragePrinciples of Operation PMG optionalNonlinear Loading InstallationParallel Operation Preparation for USEEND Play Testing Generator MountingTorsional Vibration Wiring Connections Environmental ConsiderationsLOW WYE Connection Double Delta -- Single Phase Connection Operation PRE-START InspectionSTART-UP Maintenance Shutdown ProcedureTesting Drying WindingsGeneral ServiceDiode Testing Field FlashingBearing Replacement Bearing RemovalTroubleshooting Returned GoodsGenerator Produces no Voltage Generator Produces LOW VOLTAGE, no LoadGenerator Produces LOW Voltage When Load Applied Generator Produces Fluctuating VoltageGenerator Produces High Voltage Generator is Overheating Generator Produces Mechanical NoiseSpecifications Parts List Single Bearing Parts List Dual Bearing Rules for Safe Trailer Operation Towing VehicleElectrical Trailer Wiring Towing Heavy Trailer LoadsSafety Checks Trailer Light KIT Wiring Instructions Trailer Light Mounting and ConnectionLimited Warranty Owner’s Responsibilities Page California Proposition 65 Warning