M300EU OPERATING INSTRUCTIONS | M300EU |
| Addendum to M300E/EM Manual P/N 04288 |
6.7.3. SELECTING A TEST CHANNEL FUNCTION FOR OUTPUT A4
This section replaces Section 6.13.5.5 of the M300E/EM Operators Manual (P/N 04288)
The Test Functions available to be reported on analog output A4 are:
Table | Test Channels Functions Available on the M300EU’s Analog Output | ||||
|
|
|
| ||
TEST CHANNEL | DESCRIPTION | ZERO | FULL SCALE | ||
|
|
|
|
| |
NONE |
| TEST CHANNEL IS TURNED OFF |
| ||
|
|
|
|
| |
|
| The raw output of the optical bench’s IR |
|
| |
CO MEAS |
| detector during the measure phase of the m/r | 0 mV | 5000 mV* | |
|
| cycle |
|
| |
CO REF |
| The raw output of the optical bench’s IR |
|
| |
| detector during the reference phase of the | 0 mV | 5000 mV* | ||
|
| m/r cycle |
|
| |
SAMPLE PRESSURE | The pressure of gas in the optical bench’s | 0 "Hg | 40 | ||
sample chamber | |||||
|
|
|
| ||
SAMPLE FLOW |
| The gas flow rate through the optical bench’s | 0 cm3/min | 6000 cm3/min | |
|
| sample chamber |
|
| |
SAMPLE TEMP |
| The temperature of gas in the optical bench’s | 0 C° | 70 C° | |
| sample chamber | ||||
|
|
|
| ||
BENCH TEMP |
| The temperature of optical bench’s itself | 0 C° | 70 C° | |
|
|
|
|
| |
WHEEL TEMP |
| The temperature of GFC wheel | 0 C° | 70 C° | |
|
|
|
|
| |
|
| The temperature of the circulating air inside |
|
| |
OVEN TEMP |
| the convection oven section of the M300EU’s | 0 C° | 70 C° | |
|
| interior. |
|
| |
PHT DRIVE |
| The drive voltage being supplied to the | 0 mV | 5000 mV | |
| thermoelectric coolers of the IR | ||||
|
| the sync/demod Board. |
|
| |
TEMP4 |
| SPARE |
|
| |
|
|
|
|
|
Once a function is selected, the instrument not only begins to output a signal on the analog output, but also adds TEST to the list of Test Functions viewable via the Front Panel Display.
38 | 05831 Rev. 01 |