Teledyne
Model 300EU
manual
User Notes, M300EU, 05831 Rev, Addendum to M300E/EM Manual P/N
Troubleshooting
Specs
Install
Signal Name
Password
Warranty
Maintenance
VAC Configuration
Gas Flow Problems
Setup
Page 52
EPA Protocol Calibration
M300EU
Addendum to M300E/EM Manual P/N 04288
USER NOTES:
44
05831 Rev. 01
Page 51
Page 53
Image 52
Page 51
Page 53
Contents
ADDENDUM TO M300E/EM MANUAL P/N
MODEL 300EU CO ANALYZER WITH AUTO-REFERENCE
TELEDYNE INSTRUMENTS ADVANCED POLLUTION INSTRUMENTATION DIVISION TAPI
9480 CARROLL PARK DRIVE SAN DIEGO, CALIFORNIA USA
Page
SAFETY MESSAGES
USER NOTES
M300EU
GENERAL SAFETY HAZARD
Addendum to M300E/EM Manual P/N
TABLE OF CONTENTS
LIST OF FIGURES
LIST OF TABLES
LIST OF APPENDICES
APPENDIX A-4 Model 300EU Signal I/O Definitions, Revision K.6
USER NOTES
1. INTRODUCTION
1.1. REFERENCE NUMBERING CONVENTION
1.2. M300EU OVERVIEW
any time the instrument is in SETUP mode
USER NOTES
2. SPECIFICATIONS, APPROVALS AND WARRANTY
2.1. SPECIFICATIONS
M300EU Basic Unit Specifications
05514 Rev A1
2.4. WARRANTY
2.2. EPA EQUIVALENCY DESIGNATION
2.3. CE MARK COMPLIANCE
05831 Rev
3. GETTING STARTED
3.1. UNPACKING THE M300EU
3.2. M300EU ANALYZER LAYOUT
OPTICAL BENCH
3.3.1. POWER CONNECTION
3.3. ELECTRICAL CONNECTIONS
M300EU
Figure 3-2 M300EU Internal Gas Flow
Analog Output Data Type Default Settings
3.3.2. ANALOG OUTPUT Connections
Figure 3-3 M300EU Analog Output Connector
3.3.3. CONNECTING THE STATUS OUTPUTS
Analog Output Pin Outs
Table 3-3 Status Output Pin Assignments
Output #
3.4. INITIAL OPERATION OF THE M300EU
3.4.1. STARTUP AND WARM UP OF THE M300EU
3.4.2. WARNING MESSAGES
MESSAGE
3.4.3. FUNCTIONAL CHECK
The Test functions available from the front panel of the M300EU are
3.5.2. BASIC CO CALIBRATION SETUP
3.5. INITIAL CALIBRATION
3.5.1. PRE-CALIBRATION STABILIZATION
3.5.2.1. Calibration Gases
3.5.3. BASIC CO CALIBRATION PROCEDURE
STEP 1 - SET LIMITS
STEP 2 - DILUTION RATIO
STEP 3 - SET CO SPAN GAS CONCENTRATION
4. FREQENTLY ASKED QUESTIONS & GLOSSARY
USER NOTES
5. OPTIONAL HARDWARE AND SOFTWARE
OPTION
DESCRIPTION
300E
5.1. CALIBRATION VALVE OPTIONS FOR THE M300EU
5.1.1. ZERO SPAN VALVES OPT 50A
TOLL-FREE FAX TEL E-MAIL api-sales@teledyne.com
M300EU Internal Pneumatic Flow- Zero/Span Valves OPT 50A
SAMPLE CHAMBER
5.1.2. ZERO SPAN VALVES WITH IZS OPT 51B
Scrubber
5.1.3. Zero Span Valves with IZS and Shutoff VALVE OPT 51B
6. M300EU OPERATING INSTRUCTIONS
6.2. OPERATING MODES
M300EU Operating Modes
sample gas stream is being routed through the CO scrubber of the auto
reference gas path
6.2.1. AUTO-REFERENCE MODE AREF
SETUP
Mode Field
AUTO-REF RANGE = 50.000 PPM
6.2.2. TEST FUNCTIONS
Units
Table 6-2 Test Functions Defined
Parameter
6.3. SETUP Æ RNGE ANALOG OUTPUT REPORTING RANGE CONFIGURATION
6.3.1. PHYSICAL RANGE VERSUS ANALOG OUTPUT REPORTING RANGES
6.3.2. ANALOG OUTPUT RANGES FOR CO CONCENTRATION
ANALOG OUT
DEFAULT SETTINGS
SNGL
DUAL
AUTO
This is the default reporting range mode for the analyzer
To set the ranges press following keystroke sequence
M300EU OPERATING INSTRUCTIONS
6.3.6. SETUP Æ RNGE Æ UNIT SETTING THE REPORTING RANGE UNIT TYPE
weight/volume units CO ppb x 1.25 = CO ug/m3 CO ppm x 1.25= CO mg/m3
Pressure STP
Consult your local regulations for the STP used by your agency
6.4.1. ADJUSTING THE A-REF MODE CYCLE TIME
6.4.2. FORCING AN AUTO-REFERENCE MEASUREMENT
To manually start an auto-reference measurement cycle, press
M300EU
6.5. SETUP Æ MORE Æ VARS INTERNAL VARIABLES VARS
Table 6-3 Test Functions Defined
VARIABLE
DESCRIPTION
6.6. SETUP Æ MORE Æ DIAG USING THE DIAGNOSTICS FUNCTIONS
DIAG I/O
DIAG AOUT
DIAG AIO
6.7. ANALOG OUTPUT CONFIGURATION
6.7.1. ANALOG I/O CONFIGURATION
THE ANALOG I/O CONFIGURATION SUBMENU
DIAG - Analog I/O Functions
4. Choose a Test Channel parameter to be output on the channel
ANALOG OUTPUT SIGNAL TYPE AND RANGE SELECTION
TURNING THE ANALOG OUTPUT OVER-RANGE FEATURE ON/OFF
6.13.5.7 SETTING THE REPORTING RANGE SCALE FOR AN ANALOG OUTPUT
6.13.5.8 SETTING DATA UPDATE RATE FOR AN ANALOG OUTPUT
6.7.2. CALIBRATION OF THE ANALOG OUTPUTS
MANUAL CALIBRATION OF ANALOG OUTPUT CONFIGURED FOR VOLTAGE RANGES
ENABLING OR DISABLING THE AUTO-CAL FOR AN INDIVIDUAL ANALOG OUTPUT
AUTOMATIC ANALOG OUTPUT CALIBRATION
6.7.3. SELECTING A TEST CHANNEL FUNCTION FOR OUTPUT A4
Test Channels Functions Available on the M300EU’s Analog Output
TEST CHANNEL
ZERO
6.7.4. HESSEN PROTOCOL
Table 6-7 M300EU Hessen GAS ID List
Default Hessen Status Bit Assignments
7. CALIBRATION PROCEDURES
manual for troubleshooting tips MANUAL CALIBRATION
REQUIRED EQUIPMENT, SUPPLIES AND EXPENDABLES
STEP3 - ZERO/SPAN CALIBRATION
7.9.1 SECTION O2 SENSOR CALIBRATION PROCEDURE
7.9.2 CO2 SENSOR CALIBRATION PROCEDURE
MANUAL CALIBRATION WITH ZERO/SPAN VALVES
MANUAL CALIBRATION CHECKS WITH ZERO/SPAN VALVES
8. EPA PROTOCOL CALIBRATION
USER NOTES
9. INSTRUMENT MAINTENANCE
9.1. PERFOMING AN AUTO-REFERENCE MEASUREMENT AFTER MAINTENANCE
USER NOTES
Table 9-1 M300EU Test Function Record
STABILITY
CO MEAS
MR RATIO
USER NOTES
10. THEORY OF OPERATION
10.1. MEASUREMENT METHOD
10.1.1. AUTO-REFERENCE RATIO
Figure 10-1 M300EU Gas flow during Auto-Reference Measurements
10.2. PNEUMATIC OPERATION
10.2.1. THE A-REF CARBON MONOXIDE SCRUBBER
Figure 10-2 Auto-Reference Measurement Cycle
This includes calibration gases such as zero air and span gas
10.2.2. THE A-REF VALVE ASSEMBLY
10.2.3. THE NAFION→ DRYER
Auto-Reference Valve Operating States
Figure 10-3 Semi-Permeable Membrane Drying Process
The dryer consists of a bundle of 0.030 O.D. Nafion→ tubes housed within a single large tube shell. Sample gas flows within the Nafion tubes while water vapor absorbs into the tubular membrane walls and is removed. Moisture permeating the tubing is carried away by a dry purge gas within the shell that flows countercurrent to the sample gas
10.3. ELECTRONIC OPERATION
10.3.1. OVERVIEW
Figure 10-4 M300EU Electronic Overview Block Diagram
Aout
10.3.2.1. Temperature Control of the Convection Oven
10.3.2. THE RELAY PCA
Figure 10-5 M300EU Heating Control Block Diagram
10.3.2.2. Oven Heaters AC Power Configuration
115 VAC Configuration
230 VAC Configuration
Figure 10-6 M300EU Oven Heater Configuration Jumpers
10.3.3. MOTHERBOARD
10.3.2.3. Status LED’s
10.3.3.1. A to D Conversion
10.3.3.2. Sensor Inputs
RELAY PCA
10.3.4. POWER DISTRIBUTION
Figure 10-8 M300EU Distribution Block Diagram
Page
11. TROUBLESHOOTING & REPAIR
11.1. GENERAL NOTES
MAINTENANCE PERSONNEL ONLY
PROCEDURES
Warning Messages - Indicated Failures
11.2. FAULT DIAGNOSIS WITH WARNING MESSAGES
Table continued on next page
Warning Messages - Indicated Failures cont
Sample flow rate is
11.2.1. FAULT DIAGNOSIS WITH TEST FUNCTIONS
Table 11-2 Test Functions - Indicated Failures
table continued
INDICATED FAILURES
Test Functions - Indicated Failures
Values outside range indicate
11.2.2. RELAY BOARD STATUS LED’S
Faulty Connectors/Wiring
Table 11-3 Relay Board Status LED Failure Indications
Voltage displayed should change. If not
11.4. OTHER PERFORMANCE PROBLEMS
11.3. GAS FLOW PROBLEMS
11.4.1. Unexplained DRIFT
11.5. SUBSYSTEM CHECHOUT
11.5.1. RELAY BOARD
11.5.2. MOTHERBOARD
11.5.2.1. A/D Functions
11.6. TECHNICAL ASSISTANCE
USER NOTES
APPENDIX A - Version Specific Software Documentation
APPENDIX A-2 M300EU Setup Variables Available Via Serial I/O
APPENDIX A-4 M300EU Signal I/O Definitions
M300EU Addendum to M300E/EM Manual
TEST1
CLR1
MSG1
Figure A-2 Primary Setup Menu Except iDAS
Figure A-3 Primary Setup Menu Æ iDAS Submenu
Figure A-4 Secondary Setup Menu Æ COMM and VARS Submenus
Figure A-5 Secondary Setup Menu Æ Hessen Protocol Submenu
ENTER PASSWORD
Auto Cal feature is OFF or the range is set for
Figure A-6 DIAG Menu
Press ENTR
APPENDIX A-2 Setup Variables For Serial I/O, Revision K.6
APPENDIX A-2 Setup Variables For Serial I/O, Revision K.6
Table continues
CO2FILTPCT
O2FILTPCT
A-10
STDO2CELLTEMP
APPENDIX A-3 Warnings and Test Functions, Revision K.6
NAME
MESSAGE TEXT
A-11
Table A-5
A-12
These gases not applicable to the M300EU
These gases not applicable to the M300EU
Signal Name
Bit or Channel
Description
Number
OVTMPW Internal box temperature #2/oven warning
APPENDIX A-5 M300EU iDAS Parameters Revision K.6
A-14
A-15
CO2OFS
O2SLPE
O2OFST
APPENDIX A-6 Terminal Command Designators, Revision K.6
A-16
APPENDIX B - M300EU SPARE PARTS & EXPENDABLES
APPENDIX B - M300EU SPARE PARTS & EXPENDABLES
European standard EN
05925 Rev A
M300EU Addendum to M300E/EM Manual
Related pages
Troubleshooting for Sprint Nextel SP7084
DIMENSIONS/SPECIFICATIONS for Kenmore 625.34857
Error Message Description for Xantrex Technology XG 850
Performance Chart for Graco 256200
Unspecified or 0.0.0.0 RAS IP address When you display for RSA Security 6.1
Complete accessory installation for Weber 700 LX
Parts List for Graco 2562
Language code list for Toshiba HD-A2KU
How does the rechargeable battery work in the GPX TV DVD Combo?
Read about battery power
Top
Page
Image
Contents