Emerson GXT3-6000RT208 Removable Power Distribution Box, PD2-006, Receptacles four L6-20R

Page 15

Major Components

3.2Removable Power Distribution Box

The UPS is shipped with a power distribution pack installed. This box contains the UPS input circuit breaker.

Figure 6 Power distribution models for 5000VA and 6000VA models of Liebert® GXT3

Output Power Breakers

Maintenance for Pigtails

Bypass Breaker

Input Power

Breaker

L14-30 Input

Power Connector

PD2-001 shown as example;

similar features on other distribution

boxes arranged differently

Push Button Output Power Breakers for Two L5-20 Receptacles (second push button breaker obscured)

PD2-001

Receptacles: four 5-20; one

L14-30; one L6-30R

PD2-002

Receptacles: two 5-20R; two L6-20RPD2-005Receptacles: four L5-20R; two L6-30R

PD2-003

PD2-006

Receptacles: four L6-20R

receptacles: four 5-20R; two L6-30

 

PD2-004

Receptacles: four L5-20R; two L5-30R

9

Image 15
Contents Liebert GXT3 208V,5000-10,000VA, 6000RTL630 Page Table of Contents Specifications MaintenanceFigures Page Important Safety Instructions Information for the Protection of the Environment Glossary of Symbols Introduction DC-to-DC Converter Rectifier/Power Factor Correction PFC CircuitBattery Charger InverterDynamic Bypass BatteryMajor Components USB Port Liebert Knockouts for HardwiredMaintenance Bypass Breaker Input Input Breaker PD2-HDWR-MBS Main Frame and ElectronicsOutput Breaker Terminal Block Repo ConnectionReceptacles four 5-20R two L6-30 Removable Power Distribution BoxPD2-006 Receptacles four L6-20RInternal battery pack features Internal Battery PacksWHAT’S Included Connectors Spacers Support Bases Install the Main CabinetInstallation and Configuration Tower UPS InstallationQuantity Rack-Mount UPS InstallationInstalling the Adjustable Rack-Mount Kit-Sold Separately Operation and Display Panel Rotated Clockwise 90 DegreesRetaining latch UPS or battery813mm DepthInstallation and Configuration External battery cabinets connected to 6000VA Liebert GXT3 External Battery Cabinet InstallationPower distribution box removal from 5000 and 6000VA models Connect Input/Output PowerInstall the Power Distribution Box on 5000 and 6000VA Models Distribution Box Electrical Connections Branch circuit breaker ratingsUnit Rating Maximum Breaker Rating Terminal Block Connections Electrical specificationsIT Power System Configuration-LiebertGXT3-6000RTL630Only ConnectorsRemove Screws Configuration Program Features Configuration ProgramWhat You Will Need Standby/Manual Bypass Button ON/Alarm Silence/Manual Battery Test ButtonControls and Indicators Upper indicator for L1 Lower for L2Load Level Indicators 4 Green, 1 Amber Battery Level Indicators 5 GreenLiebert GXT3 has UPS Status Indicators UPS status indicatorsUPS Status Indicator Icon Color Description Startup Checklist for the Liebert GXT3 Initial Startup and Electrical ChecksOperation Put the Liebert GXT3 in Manual Bypass Manual Battery TestDisconnecting Input Power from the Liebert GXT3 Maintenance BypassCommunication Battery Mode ShutdownCommunication Interface Port Terminal BlockOn Battery Low BatteryLiebert IntelliSlot Communication Cards Remote Emergency Power Off Repo switch connection diagramLiebert MultiLink Replacing the Internal Battery Pack MaintenanceBattery Replacement Procedures Precautions Battery ChargingReplacing the Power Module on 8000 and 10,000VA models Checking UPS StatusChecking UPS Functions Maintenance Indicator Diagnosis/Audible alarm UPS SymptomsTroubleshooting IndicatorsTroubleshooting table TroubleshootingAudible Alarm Audible alarm descriptionTroubleshooting table cont’d UPS specifications-5000, 6000, 8000 and 10,000 models SpecificationsModel Number GXT3-6000RTL630 Model Rating UPS specifications-LiebertGXT3-6000RTL630Dimensions, Rack Mount, W X D X H, in. mm Weight, lb kgInternal battery cabinet specifications Operating temperature parametersExternal battery cabinet specifications Model Number Battery ParametersSee Table Environmental Power Distribution Box Model # Batteries Capacity 5kVA 6kVA 8kVA 10kVA 6kVA L630 Battery run time, minutesNumber Load Percent 208/120VAC RT 220VAC TowerAuto-Learning Battery Run Times Page Care NetIs t Twork