Emerson GXT3-6000RT208 user manual Internal Battery Packs, Internal battery pack features

Page 16

Major Components

Figure 7 Power distribution models for 8000VA and 10,000VA models of Liebert® GXT3

5-20R Output

Receptacles

Push Button Circuit Breakers

for 5-20R Receptacles

5-20R Output

Receptacles

PD2-101

Receptacles: two L6-30; eight 5-20R

PD2-102

Receptacles: four L6-20R four 5-20R

PD2-103

Receptacles: four L6-30R four 5-20R

PD2-104

Receptacles:

four 5-20R two L6-30R two L6-20R

similar features on other

distribution boxes arranged differently

Output Circuit Breaker

Switch for L6-30R Pigtail #1

L6-30ROutput

Receptacles

2

1

Output Circuit Breaker Switch for L6-30R Pigtail #2

PD2-105

Receptacles:

four 5-20R two L5-30R two L5-20R

PD2-106

Receptacles: four L6-20R four L5-20R

3.3Internal Battery Packs

The UPS has two internal battery packs behind a battery access door on the front of the unit. Each internal battery pack is fitted with a connector to link to the UPS.

Figure 8 Internal battery pack features

Battery Handle

Battery Connector

Liebert GXT3 8000 and 10,000VA

battery packs shown; 5000 and 6000VA battery packs

have same features

Front of Battery Pack

10

Image 16
Contents Liebert GXT3 208V,5000-10,000VA, 6000RTL630 Page Table of Contents Maintenance SpecificationsFigures Page Important Safety Instructions Information for the Protection of the Environment Glossary of Symbols Introduction Rectifier/Power Factor Correction PFC Circuit Battery ChargerInverter DC-to-DC ConverterBattery Dynamic BypassUSB Port Liebert Knockouts for Hardwired Maintenance Bypass Breaker Input Input Breaker PD2-HDWR-MBSMain Frame and Electronics Major ComponentsTerminal Block Repo Connection Output BreakerRemovable Power Distribution Box PD2-006Receptacles four L6-20R Receptacles four 5-20R two L6-30Internal Battery Packs Internal battery pack featuresWHAT’S Included Install the Main Cabinet Installation and ConfigurationTower UPS Installation Connectors Spacers Support BasesRack-Mount UPS Installation Installing the Adjustable Rack-Mount Kit-Sold SeparatelyOperation and Display Panel Rotated Clockwise 90 Degrees QuantityUPS or battery 813mmDepth Retaining latchInstallation and Configuration External Battery Cabinet Installation External battery cabinets connected to 6000VA Liebert GXT3Connect Input/Output Power Power distribution box removal from 5000 and 6000VA modelsInstall the Power Distribution Box on 5000 and 6000VA Models Branch circuit breaker ratings Distribution Box Electrical ConnectionsUnit Rating Maximum Breaker Rating Electrical specifications Terminal Block ConnectionsConnectors IT Power System Configuration-LiebertGXT3-6000RTL630OnlyRemove Screws Configuration Program Configuration Program FeaturesWhat You Will Need ON/Alarm Silence/Manual Battery Test Button Controls and IndicatorsUpper indicator for L1 Lower for L2 Standby/Manual Bypass ButtonBattery Level Indicators 5 Green Load Level Indicators 4 Green, 1 AmberLiebert GXT3 has UPS status indicators UPS Status IndicatorsUPS Status Indicator Icon Color Description Initial Startup and Electrical Checks Startup Checklist for the Liebert GXT3Operation Manual Battery Test Disconnecting Input Power from the Liebert GXT3Maintenance Bypass Put the Liebert GXT3 in Manual BypassBattery Mode Shutdown Communication Interface PortTerminal Block CommunicationLow Battery On BatteryLiebert IntelliSlot Communication Cards Repo switch connection diagram Remote Emergency Power OffLiebert MultiLink Maintenance Replacing the Internal Battery PackBattery Replacement Procedures Battery Charging PrecautionsChecking UPS Status Replacing the Power Module on 8000 and 10,000VA modelsChecking UPS Functions Maintenance UPS Symptoms TroubleshootingIndicators Indicator Diagnosis/Audible alarmTroubleshooting Audible AlarmAudible alarm description Troubleshooting tableTroubleshooting table cont’d Specifications UPS specifications-5000, 6000, 8000 and 10,000 modelsUPS specifications-LiebertGXT3-6000RTL630 Dimensions, Rack Mount, W X D X H, in. mmWeight, lb kg Model Number GXT3-6000RTL630 Model RatingOperating temperature parameters Internal battery cabinet specificationsBattery Parameters External battery cabinet specifications Model NumberSee Table Environmental Power Distribution Box Model # Battery run time, minutes Number Load Percent 208/120VAC RT220VAC Tower Batteries Capacity 5kVA 6kVA 8kVA 10kVA 6kVA L630Auto-Learning Battery Run Times Page Net Is tTwork Care