Contents
Liebert GXT3 208V,5000-10,000VA, 6000RTL630
Page
Table of Contents
Maintenance
Specifications
Figures
Page
Important Safety Instructions
Information for the Protection of the Environment
Glossary of Symbols
Introduction
Inverter
Rectifier/Power Factor Correction PFC Circuit
Battery Charger
DC-to-DC Converter
Battery
Dynamic Bypass
Main Frame and Electronics
USB Port Liebert Knockouts for Hardwired
Maintenance Bypass Breaker Input Input Breaker PD2-HDWR-MBS
Major Components
Terminal Block Repo Connection
Output Breaker
Receptacles four L6-20R
Removable Power Distribution Box
PD2-006
Receptacles four 5-20R two L6-30
Internal Battery Packs
Internal battery pack features
WHAT’S Included
Tower UPS Installation
Install the Main Cabinet
Installation and Configuration
Connectors Spacers Support Bases
Operation and Display Panel Rotated Clockwise 90 Degrees
Rack-Mount UPS Installation
Installing the Adjustable Rack-Mount Kit-Sold Separately
Quantity
Depth
UPS or battery
813mm
Retaining latch
Installation and Configuration
External Battery Cabinet Installation
External battery cabinets connected to 6000VA Liebert GXT3
Connect Input/Output Power
Power distribution box removal from 5000 and 6000VA models
Install the Power Distribution Box on 5000 and 6000VA Models
Unit Rating Maximum Breaker Rating
Distribution Box Electrical Connections
Branch circuit breaker ratings
Electrical specifications
Terminal Block Connections
Remove Screws
IT Power System Configuration-LiebertGXT3-6000RTL630Only
Connectors
What You Will Need
Configuration Program Features
Configuration Program
Upper indicator for L1 Lower for L2
ON/Alarm Silence/Manual Battery Test Button
Controls and Indicators
Standby/Manual Bypass Button
Liebert GXT3 has
Load Level Indicators 4 Green, 1 Amber
Battery Level Indicators 5 Green
UPS Status Indicator Icon Color Description
UPS Status Indicators
UPS status indicators
Operation
Startup Checklist for the Liebert GXT3
Initial Startup and Electrical Checks
Maintenance Bypass
Manual Battery Test
Disconnecting Input Power from the Liebert GXT3
Put the Liebert GXT3 in Manual Bypass
Terminal Block
Battery Mode Shutdown
Communication Interface Port
Communication
Liebert IntelliSlot Communication Cards
On Battery
Low Battery
Liebert MultiLink
Remote Emergency Power Off
Repo switch connection diagram
Battery Replacement Procedures
Replacing the Internal Battery Pack
Maintenance
Battery Charging
Precautions
Checking UPS Functions
Replacing the Power Module on 8000 and 10,000VA models
Checking UPS Status
Maintenance
Indicators
UPS Symptoms
Troubleshooting
Indicator Diagnosis/Audible alarm
Audible alarm description
Troubleshooting
Audible Alarm
Troubleshooting table
Troubleshooting table cont’d
Specifications
UPS specifications-5000, 6000, 8000 and 10,000 models
Weight, lb kg
UPS specifications-LiebertGXT3-6000RTL630
Dimensions, Rack Mount, W X D X H, in. mm
Model Number GXT3-6000RTL630 Model Rating
Operating temperature parameters
Internal battery cabinet specifications
See Table Environmental
External battery cabinet specifications Model Number
Battery Parameters
Power Distribution Box Model #
220VAC Tower
Battery run time, minutes
Number Load Percent 208/120VAC RT
Batteries Capacity 5kVA 6kVA 8kVA 10kVA 6kVA L630
Auto-Learning Battery Run Times
Page
Twork
Net
Is t
Care