Emerson MSM400 manual Contents

Page 2

CONTENTS

 

 

 

Page

1.

PRODUCT INTRODUCTION

5

 

1.1

The MSM400 slurry monitoring system

5

 

1.2

Description

5

2.SENSOR TYPES

 

2.1

Safety Precautions

7

 

2.2

Hazardous Area systems

7

 

2.3

Quick Start guide

8

3.

CONTROL UNITS

9

 

3.1

MSM400 Displays and Keypad

9

 

3.2

Specifications

10

4.INSTALLATION

4.1

Preliminary Checks

11

4.2

Pipe Section Installation

11

4.3

Suspended Sensor Installation

11

4.4

Sensor Cabling

12

4.5

Control Unit

12

4.6

Electrical Connections

13

5.PROGRAMMING

5.1

Programme Structure

16

5.2

Navigation in the Menu System

19

5.3

Diagnostic Parameters

18

5.4

Ex-Factory System Features

18

6.CALIBRATION

 

6.1

Zero Setting

18

 

6.2

Re checking Zero

19

 

6.3

Auto cal zero setting procedures

19

 

6.4

Auto cal span setting procedure

20

 

6.5

Auto cal lab values

21

 

6.6

Maximum % solids

22

 

6.7

Calibration - Alternative method

22

 

6.8

Zero setting procedure

22

 

6.9

Span Calibration Methods

22

 

6.10

Method 1-Slurry Type

22

 

6.11

Method 2-Sample Calibration

22

 

6.12

Method 3-Attenuation Value

23

7.0 PROGRAMMING THE MSM400 FUNCTIONS

24

 

7.1

Outputs

27

 

7.2

Current output

27

 

7,3

Relay Operation

27

 

7.4

Alarm

28

 

7.5

Display

28

 

7.6

Back Light

29

 

7.7

Engineering

29

 

7.8

System

29

8.

HART SMART COMMUNICATIONS

30

9.

MAINTENANCE / INSPECTION

30

APPENDICES

 

 

A1. Full Listing of Menu Structure

31-32

A2. Full List of Programme Parameter Functions

33-37

A3. HART and PSION Operating Instructions

38-40

D

Handheld Communicator - Assembly Instructions

41-59

Footnote :-

In this manual the following terms are used which refer to trademarks from other manufacturers:

HART: is the protocol adopted for the MSM400 SMART Communications.

HART is a registered trademark of the HART Communications Foundation and is a mnemonic For Highway Addressable Remote Transducer.

PSION: is the trade mark of PSION plc who manufacture the PSION ORGANISER Hand held computer.

The MOBREY SMART program is stored in a DATAPAK which is also a trademark of PSION plc, and is an accessory for the Model LZ Organiser

IP258

2

Image 2
Contents Mobrey Contents Safety Precautions ENT Sensor Connection IVE Neutral Earth MainsDisplay Product Introduction MSM400 Slurry Monitoring System Product DescriptionSlurry Characteristics Ultrasonic Attenuation versus Suspended solidsSuspended Sensor Type MSM433 Mobrey Pipe Section SensorsSensor Type Numbering System Keypad Operation Control UnitMSM400 Displays and Keypad EMC SPECIFICATIONS--MSM400Hart Preliminary Checks Pipe Section InstallationSuspended Sensor Installation Sensor Cables Control UnitTerminal Label Function Relays Hart Connections and Jumper SettingsSensor Connections Current OutputMains Supply Safety PrecautionsInitial Power UP Main Menu Toggle RUN Calibration Setup Toggle RUN Calibration Setup MonitorToggle RUN Zero Setting Initial Zero Diagnostic ParametersEX-FACTORY System Features Calibration Methods Auto CAL Auto CAL Zero Setting Procedure Rechecking ZeroAutocal Span Setting Procedure Clear Liquor Press ENT To set 23.1dB 26.2dBSample Press ENT to set 33.6dB 44.2dB Auto CAL LAB ValuesSpan CALIBRATION/GRADIENT Methods Zero Setting ProcedureMaximum % Solids Calibration Method 1-SLURRY TypeAttenuation VALUE-METHOD Start on Stop on Stop if Do not start if Duty Mode Desludge ModeNo. of operation Set Default value Max value Hrs & mins INPUT↓ Output Start Time #1 hm 730 P254 Outputs Current Output Relay Operation←−−−−−−− Lower Display AlarmMiddle Display Display option parameter number DescriptionSystem Test Current Output SettingsEngineering Frequency SET Hart Smart Communications SensorsPar No Appendix A1Main Menu SUB Menu Parameter Description Logging Alarm ReportDiagnostics EngineeringMin Max Default Value Parameter DescriptionParameter Description Min Max Default Value MSM400 MonitFrom list 3.6/21mA/hold last reading Min Max Default Value Ex-Factory Manufacturer’s Code Appendix A3 Hart and Psion Operating Instructions Hart ConsiderationsCalibration adjustments at operating conditions Smart Communication with the Mobrey MSM400Further customisation using the Smart HHC Hand Held Communicator Assembly Instructions Handheld Communicator Mobrey CKFig DII. Loop diagram Fig D1 MOBREY-CK* HHC assembly How to connect the Smart Communicator Hand Held Communicator Operation Mobrey Find Save Diary Calc Time Notes World Alarm How to drive a Psion based Smart CommunicatorTAG Tank Help D7.0 Introduction and Function menuD7.1 Monitor/Display Parameters D D7.2 Program Parameters PWorking Register Default RegisterMode KEY Safe RegisterHand Held Communicator Registers Select Data Source Printout or PC transfer of MSM400 programme data 10.0ERROR Messages on the HHC10.1Alarm and Error Messages Display of Parameter Data10.2Invalid Data Entry 10.3Communication Errors Password not OpenInstrument in Multidrop Mode Invalid Action not the Same InstrumentD0 D8 Current Output ** Set current Trim-maximum Trim-maximum 11.0Current Loop Checks and TrimmingCurrent and USE ↑ & ↓ To Trim the Output 12.0Unknown InstrumentD13.0 Smart Interfaces Compatibility D13.1 Introduction 13.3Use of multiple Smart CommunicatorsAbcdef