Parameter | Description |
| Min. | Max. | Default | |
No. |
|
|
| value | value | |
P130 |
| Span 1 @ 1MHz | Measured attenuation | - | - | 0.0 |
P131 |
| Span 1 @ 3.3MHz | Measured attenuation | - | - | 0.0 |
P132 |
| Span 2 @ 1MHz | Measured attenuation | - | - | 0.0 |
P133 |
| Span 2 @ 3.3MHz | Measured attenuation | - | - | 0.0 |
P134 |
| Span 3 @ 1MHz | Measured attenuation | - | - | 0.0 |
P135 |
| Span 3 @ 3.3MHz | Measured attenuation | - | - | 0.0 |
P140 |
| Date for Span 1 |
| - | - | 0 |
P141 |
| Date for Span 2 |
| - | - | 0 |
P142 |
| Date for Span 3 |
| - | - | 0 |
P150 |
| Lab Value 1 |
| - | - | 0 |
P151 |
| Lab Value 2 |
| - | - | 0 |
P152 |
| Lab Value 3 |
| - | - | 0 |
P160 |
| Max % Solids |
| - | - | - |
P200 |
| PV Units |
|
|
|
|
|
| The PV units can be selected from a list |
|
|
| |
|
| (%, kg/hr, lb/hr,g/l, ppm, None) | - | - | % | |
P201 |
| Density Units |
| - | - | % |
P240 |
| Description |
| - | - | - |
|
| 16 character |
| MSM400 MONIT | ||
P241 |
| Message |
| - | - | - |
|
| User set up message for HART info |
| 32 Chars |
| |
P242 |
| Tag Number - Control Unit | - | - | - | |
|
|
| MSM40055 |
| ||
|
| accordance with HART. May be entered by keypad. |
|
|
| |
P250 |
| Start On |
|
|
|
|
|
| This parameter is used to set up the mode of start |
|
|
| |
|
| for a desludge operation and is selected from a list |
|
|
| |
|
| (Time, PV, Ext. Trig) |
| 1 | 3 | none |
P251 |
| Stop On |
|
|
|
|
|
| This parameter is used to set up the mode of stop |
|
|
| |
|
| for a desludge operation and is selected from a list |
|
|
| |
|
| (Time, PV, Ext. Trig) |
| 1 | 3 | none |
P252 |
| Do not Start if |
|
|
|
|
|
| This parameter is used to set up the mode 'do not start if' |
|
|
| |
|
| for a desludge operation and is selected from a list |
|
|
| |
|
| (Light sludge, Ext trigger) | 1 | 3 | not used | |
P253 |
| Stop If select from list |
|
|
| |
|
| This parameter is used to set up the mode 'stop if' |
|
|
| |
|
| for a desludge operation and is selected from a list |
|
|
| |
|
| (Light sludge, Ext trigger) | 1 | 3 | not used | |
P254 |
| Start Time #1 |
|
|
|
|
|
| The time of day that the first desludge cycle starts | 00:00 | 23:59 | 7:00 | |
P255 |
| Interval #1 |
|
|
|
|
|
| The time interval for the first desludge cycle | 00:00 | 23:59 | 1:00 | |
P256 |
| Start Time #2 |
|
|
|
|
|
| The time of day that the second desludge cycle starts | 00:00 | 23:59 | 00:00 | |
P257 |
| Interval #2 |
|
|
|
|
|
| The time interval for the first desludge cycle | 00:00 | 23:59 | 00:00 | |
P258 |
| Max retries |
|
| Not implemented |
|
P300 | P | Sensor Serial Number | - | - | - | |
|
|
|
|
|
| |
P301 | P | Sensor Type |
| - | - | - |
P302 |
| dB Damping |
| - | - | - |
|
|
|
|
|
| IP258 |
34