Cooper Bussmann BU-945U-E 802.11 DSSS user manual Ipconfig, Arp

Page 64

Cooper Bussmann Wireless Ethernet & Device Server BU-945U-E 802.11 DSSS User Manual

”Ipconfig”

“ipconfig” can be used to show your current TCP/IP information, including your address, DNS server addresses, adapter type and so on.

In the above example ipconfig was entered in the command prompt. The reply back shows the PC’s IP address, Subnet mask and the gateway it is connected to.

Other ipconfig commands will return back more information. The hardware or MAC address of the computer may be discovered using the command ipconfig /all.

Ipconfig /? Lists all of the commands and their usages available for use.

“Arp”

Displays and modifies the IP-to-Physical address translation tables used by Address Resolution Protocol (ARP).

Once a remote computer has been pinged, this can be used to see the IP address & MAC address of the remote computer. It will also show any other devices on the network that it may be connected to.

Command used for above screen shot is “arp –a.” It shows the PC’s direct IP address of 192.168.0.17 as also shown before with ipconfig command. The other IP address shown with its associated MAC address is another device with a connection to the PC. In this example it is the IP address of a PLC connected to the PC also.

Arp – ? lists all the commands available for this function.

64

www.cooperbussmann.com/BussmannWirelessResources

3A1582Rev1.6

Image 64
Contents Read Retain FCC Notice Cooper Bussmann Application EngineeringPhone 800 a.m 500 p.m. Central, M-F 636 Fax 636 GNU Free Documentation License Important NoticeCooper Bussmann Contents Access Point vs Client BU-945U-E 802.11 630mW max powerNetwork Topology 3A1582Rev1.6 Bridge vs. Router Getting Started Quickly Antenna Installation GeneralBench test and Demo System Setup Plant and Factory InstallationsLine-of-sight installations AntennasInstallation tips Omni-directional AntennasPower Supply Serial ConnectionsDirectional Antennas RS232 Serial PortDB9 Connector Pinouts RS485 Serial Port3A1582Rev1.6 Discrete Digital Input/Output Start-up LED Indication Selecting a Channel802.11 900 MHz Channels 3A1582Rev1.6 Radio Throughput Data Throughput Based on Repeater HopsDefault Configuration Configuring the Unit for the First TimeAccessing Configuration for the First Time Power up the BU-945U-E module Enter the username user and default password userMethod 1 Set PC to same network as BU-945U-E For local addresses3A1582Rev1.6 Quick Start Configuration Quick StartNetwork Configuration Dhcp Server Configuration, Default is unchecked Wireless ports will have the same IP addressConfigured Essid of the client Save Changes and ResetSecurity Menu Encryption keys must not be all zeros, i.e3A1582Rev1.6 Radio Configuration Normal OperationTransparent Bridge Operation Router OperationBands Default is Auto Signal quality, etcDrop back to non-bursting mode Access pointDhcp Client Configuration Radio Mode BU-945U-E Only Supports the 802.11 StandardDefault distance is 20km Channel SelectionDNS Server Configuration Dhcp Server ConfigurationSpanning Tree Algorithm / Redundancy Multiple AP Repeater Mesh Network 3A1582Rev1.6 Example Extending range using WDS Site B WDS ConfigurationExample Roaming with WDS Access Points Example Adding Redundancy3A1582Rev1.6 Example WDS Routed Network Mouse, to highlight the entire row WDS Connections Routing RulesSTP Specifies a destination host Wireless Message FilteringInformation at a later time 3A1582Rev1.6 IP Address Filter Configuration MAC Address Filter ConfigurationUtilize the radio link. All other devices are blocked ARP Filter Configuration Serial Port Configuration RS-232 PPP ServerSerial Gateway Server/Client/Multicast Serial Gateway Modbus Modbus RTU to TCPModbus TCP to RTU Gateway Serial MenuMulticast Pipe Manager Digital Input/Output Port on the Client, i.e., Scada, DCS, etcMulticast Group IP Address To be the same on all communicating Multicast devicesModbus I/O Transfer 3A1582Rev1.6 Modbus TCP Configuration on I/O Transfer Menu Modbus TCP Client Mappings on I/O Transfer Menu Module Information ConfigurationModule Information Webpage Fields Remote Configuration System ToolsSetting a BU-945U-E to Factory Default Settings Configuration ExamplesExtending a Wired Network Client 2 Configuration Client 1 ConfigurationLAN B Configuration Client Configuration Access Point ConfigurationExtending Range of a Network with a Repeater Hop Diagnostics Chart Boot Status LED Indication during Start-upLED Indicator Condition Meaning RED ContinuouslyDiagnostic Information Available ConnectivityConnectivity Parameters Site SurveyStatistics Network Traffic AnalysisInternal Diagnostic Modbus Registers 9999 Both Reset module enter Ffff to reset moduleConnection Information 5014 STA OnlyStatistic Registers Utilities Testing Radio PathsPing 3A1582Rev1.6 Ipconfig ArpRoute Power Supply GeneralRadio Transceiver Serial PortsSystem Parameters Input / Output statusWeb-Based Upgrade Appendix a Firmware UpgradesACK CSMA/CACSMA/CD DhcpIPX-SPX IeeeISN SNR NATNIC SSLVoIP VPNWAN WEPDBm to mW Conversion Materials InstallationIperf Applications 3A1582Rev1.6 JPerf Application 3A1582Rev1.6 Preamble Terms and Conditions3A1582Rev1.6 No Warranty 3A1582Rev1.6 Customer Assistance