Tripp Lite AVRX550UD, AVRX750UI, AVRX750UD, AVRX550UK, AVRX550UF, AVRX550UI ON/OFF/TEST Button

Page 3

Features

Model: AVR550UF Shown

(Your model may vary)

D

F

E

A

C

GB

H

I

AON/OFF/TEST Button

To turn the UPS ON: Press and hold the ON/OFF/TEST Button for one second.* If utility power is absent, pressing the button will “cold-start” the UPS, i.e. turn it on and supply power from its batteries.**

To turn the UPS OFF: Press and hold the ON/OFF/TEST switch for one second.* The UPS will be turned completely off (deactivated).

To run a self-test:With your UPS plugged in and turned ON, press and hold the ON/OFF/ TEST button for three seconds.

CAUTION! To perform a self-test, you must hold the ON/OFF/TEST button continuously for three seconds. If you release the button too early, you will turn the UPS system OFF and cut power to connected equipment loads. To ensure you hold the button for the correct length of time, do not release the button until you hear the UPS System’s audible alarm beep twice. The first beep occurs after one second and indicates that the UPS

will turn OFF if the button is released. The second beep occurs after three seconds and indicates that the UPS will perform a self-test if the button is released.

The test will last approximately 10 seconds as the UPS switches to battery to test its load capacity and charge. All LEDs will be lit and the UPS alarm will sound. See LED descriptions below to determine the results of the self-test.

Note: You can leave connected equipment on during a self-test.

CAUTION! Do not unplug your UPS to test its batteries. This will remove safe electrical grounding and may introduce a damaging surge into your network connections.

* The alarm will beep once briefly after one second has passed. **If fully charged.

B“ON/OFF” LED: This green LED lights continuously to indicate that the UPS is ON and supplying your equipment with AC power either from a utility source or from the UPS’s internal batteries. If the UPS’s alarm is sounding (4 short beeps followed by a pause), the

UPS is operating from its internal batteries.

3

201001098 93-2976.indb 3

7/8/2010 10:42:29 AM

Image 3
Contents AVR Series UPS Systems UPS Connection Warnings Important Safety InstructionsBattery Warnings Correct Disposal of this Product UPS Location WarningsON/OFF/TEST Button Features Models AVRX550UI & AVRX750UI Input Plugs and OutletsModels AVRX550UF & AVRX750UF Models AVRX550UD & AVRX750UDTelephone/Network Protection Jacks Storage ServiceRegulatory Compliance Identification Numbers Manual del propietario Instrucciones importantes de seguridad Nota puede dejar el equipo conectado durante la autoprueba Botón de APAGADO/ENCENDIDO/PRUEBACaracterísticas continuación Modelos AVRX550UI & AVRX750UI Enchufes y tomas de entradaModelos AVRX550UF & AVRX750UF Modelos AVRX550UD & AVRX750UDEncendido / Apagado / Prueba Servicio AlmacenamientoNúmero de identificación de conformidad normativa Manuel de l’utilisateur Avertissements concernant le raccordement de l’équipement Avertissements concernant l’emplacement de l’ASIConsignes importantes de sécurité Avertissements concernant le raccordement de l’ASIBouton ON/OFF/TEST MARCHE/ARRÊT/TEST Caractéristiques suite Prises d’entrée et de sortie Caractéristiques suiteInstallation Réparation StockageNuméros d’identification de conformité réglementaire Benutzerhandbuch Geräteanschlusswarnungen Wichtige SicherheitshinweiseUSV-Standortwarnungen USV-AnschlusswarnungenEIN/AUS/TEST-Taste Funktionen Fortsetzung Modelle AVRX550UI & AVRX750UI Eingangsstecker und AusgängeModelle AVRX550UF & AVRX750UF Modelle AVRX550UD & AVRX750UDSie den Installationsanweisungen. Wenn die Wartung LagerungIdentifizierungsnummern zur Einhaltung von Richtlinien Руководство для пользователя Важные правила техники безопасности Кнопка ON/OFF/TEST Технические характеристики продолжение Штепсельные вилки и розетки Коммуникационный порт USB только Хранение Идетификационные номера соответствия нормативным документам