Delta Electronics VFD-XXXE quick start Preface

Page 1

Preface

Thank you for choosing DELTA’s high-performance VFD-E Series. The VFD-E Series is manufactured with high-quality components and materials and incorporate the latest microprocessor technology available.

Getting Started

This quick start will be helpful in the installation and parameter setting of the AC motor drives. To guarantee safe operation of the equipment, read the following safety guidelines before connecting power to the AC motor drives. For detail information, refer to the VFD-E User Manual on the CD supplied with the drive.

DANGER!

1.AC input power must be disconnected before any wiring to the AC motor drive is made.

2.A charge may still remain in the DC-link capacitors with hazardous voltages, even if the power has been turned off. To prevent personal injury, please ensure that power has turned off before opening the AC motor drive and wait ten minutes for the capacitors to discharge to safe voltage levels.

3.Never reassemble internal components or wiring.

4.The AC motor drive may be destroyed beyond repair if incorrect cables are connected to the input/output terminals. Never connect the AC motor drive output terminals U/T1, V/T2, and W/T3 directly to the AC mains circuit power supply.

5.Ground the VFD-E using the ground terminal. The grounding method must comply with the laws of the country where the AC motor drive is to be installed. Refer to the Basic Wiring Diagram.

6.VFD-E series is used only to control variable speed of 3-phase induction motors, NOT for 1-phase motors or other purpose.

7.VFD-E series is the specific drive for the elevator door and other automatic door control, NOT for those devices that may cause personal injury, such as life support equipment or any life safety situation.

8.To prevent drive damage, the RFI jumper connected to ground shall be cut off if the AC motor drive is installed on an ungrounded power system or a high resistance-grounded (over 30 ohms) power system or a corner grounded TN system.

WARNING!

1.DO NOT use Hi-pot test for internal components. The semi-conductor used in AC motor drive easily damage by high-pressure.

2.There are highly sensitive MOS components on the printed circuit boards. These components are especially sensitive to static electricity. To prevent damage to these components, do not touch these components or the circuit boards with metal objects or your bare hands.

3.Only quality person is allowed to install, wire and maintain AC motor drive.

CAUTION!

1.Some parameters settings can cause the motor to run immediately after applying power.

2.DO NOT install the AC motor drive in a place subjected to high temperature, direct sunlight, high humidity, excessive vibration, corrosive gases or liquids, or airborne dust or metallic particles. Only use AC motor drives within specification. Failure to comply may result in fire, explosion or electric shock. To prevent personal injury, please keep children and unqualified people away from the equipment.

3.When the motor cable between AC motor drive and motor is too long, the layer insulation of the motor may be damaged. Please use a frequency inverter duty motor or add an AC output reactor to prevent damage to the motor. Refer to appendix B Reactor for details.

4.The rated voltage for AC motor drive must be 240V and the mains supply current capacity must be 5000A RMS.

English- 1

Image 1
Contents Preface Voltage Class 115V Class SpecificationsGeneral Specifications SL2 VT2 TL3 WT3 Basic Wiring Diagram+/B1 Signal Description PNP mode without external powerDescription of the Digital Keypad KPE-LE02 Optional To shift data Operation Steps of the Digital KeypadFrame Power Terminals Torque Wire Wire Type Power Terminals and Control TerminalsTerminal Symbol Terminal ExplanationsControl Terminals Explanations Specification for the Control TerminalsFrame Control Terminals Torque Group 0 User Parameters Summary of Parameter SettingsModels Explanation Settings FactoryNot for VFD*E*C models VFD*E*C modelsGroup 1 Basic Parameters For VFD*E*C models, the factory setting isExplanation Settings Factory AVI2 Group 2 Operation Method ParametersUP/DOWN For VFD*E*C models Explanation Settings Factory SettingGroup 3 Output Function Parameters Group 4 Input Function Parameters Not for VFD*E*CFor VFD*E*C For VFD*E*C models Models, the factory Quick Stop Only for VFD*E*C models Setting is 23.Bit5=1MI6 used by PLC Group 6 Protection Parameters Group 5 Multi-Step Speeds ParametersExplanation Settings Factory FLA Group 7 Motor ParametersSetting Group 8 Special Parameters Group 9 Communication Parameters Only for VFD*E*C Address only for VFD*E*C modelsOnly for VFD*E*C Models Group 10 PID Control ParametersParameters for Extension Card MO3/RA3 MO2/RA2MO4/RA4 MO5/RA5Explanation Settings Quick Stop Only for VFD*E*C models Group 13 PG function Parameters for Extension Card Fault CodesPLC not for VFD*E*C models Over voltage Over currentOverheating OverloadCC current clamp OV hardware error Fault Fault Descriptions Corrective Actions Name OverloadGFF hardware error OC hardware errorPhase error Fault Fault Descriptions Corrective Actions NameTemperature sensor error PID feedback signal errorFrame Dimensions are in mm inchH1 H Frame C Unit mm inch